8808A 120V Fluke Electronics, 8808A 120V Datasheet - Page 69

DMM 5.5 RES RS-232 INTERFACE

8808A 120V

Manufacturer Part Number
8808A 120V
Description
DMM 5.5 RES RS-232 INTERFACE
Manufacturer
Fluke Electronics
Type
Digital (DMM)r
Datasheets

Specifications of 8808A 120V

Includes
Test Leads
Style
Bench
Display Digits
5.5
Display Type
VFD, Dual
Display Count
200000
Function
Voltage, Current, Resistance, Frequency
Functions, Extra
Continuity, dB, Diode Test
Features
Hold, Min/Max, RS-232 Port
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Not applicable / RoHS non-compliant
Other names
614-1068
Triggering Output
External Triggering from the Front Panel
Type
1
2
3
4
5
+1.2345E+6(format 1)
+12.345E+6 OHM(format 2)
+/- 1.0E+9
The Meter takes measurements when triggered to do so. There are five trigger types,
which are described in Table 4-3. Triggers fall into two basic categories:
A measurement can be externally triggered as follows:
For use of the *TRG command, see “Common Commands.”
To enable external triggering from the front panel, perform the following procedure:
1. Press Q then J. Ext Trig and a number corresponding to the selected trigger
2. Press U or V to step through the trigger type list. Highlight the trigger type as
3. Press J to trigger a measurement. (Each time you press J you trigger a
4. To return the Meter to its internal (continuous) trigger state, perform step 3 and select
type (1, 2, 3, 4, or 5) are displayed. See Table 4-3 for trigger types.
follows, and then press R for two seconds to select it.
Select trigger type 2 to disable the settling delay; or select trigger type 3 to enable the
settling delay. See Table 4-3 for typical settling delays.
When trigger type 2 or 3 is selected, Ext Trig is displayed confirming that you are
not in the remote mode and an external trigger is enabled. (If you are not in the
remote mode, you will not be able to trigger measurements from the front panel.)
measurement.)
trigger type 1.
Internal trigger, which triggers measurements continuously.
External trigger, which triggers a measurement at the direction of the user.
External trigger with rear trigger disabled. This includes trigger types 2 and 3, as
described in Table 4-3.
External trigger with rear trigger enabled. This includes trigger types 4 and 5, as
described in Table 4-3.
*TRG command
External
External
External
External
Trigger
Internal
Table 4-3. Trigger Types
Measured value of 1.2345M
Measured value of 12.345Mohms
Overload (0L on the display)
Rear Trigger
Operating the Meter Using the Computer Interface
Disabled
Disabled
Disabled
Enabled
Enabled
Settling Delay
Off
On
Off
On
Triggering Output
4
4-9