E3G-L35 Omron, E3G-L35 Datasheet - Page 9

Photoelectric Sensors - Industrial CONVERGENT 200mm NPN CONN.

E3G-L35

Manufacturer Part Number
E3G-L35
Description
Photoelectric Sensors - Industrial CONVERGENT 200mm NPN CONN.
Manufacturer
Omron
Type
Photoelectric Sensorr
Series
E3Gr
Datasheet

Specifications of E3G-L35

Features
Light ON / Dark ON
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
- 25 C
Operating Supply Voltage
10 V to 30 V
Sensing Distance
50 mm
Output Configuration
NPN
Sensing Method
Reflective, Diffuse
Sensing Object
Black Paper, Kodak® White Paper
Sensing Light
Infrared
Mounting Type
Bracket Mount
Current - Supply
65mA
Voltage - Supply
10 V ~ 30 V
Package / Case
Module, Connector
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
E3G-L1/L3
J ADJUSTMENTS
If the sensor is not in stable operation due to color differences, make a fine adjustment of the threshold level and confirm that the sensor
operates in stable state. Refer to Manual Teaching (Fine Distance Setting.
Adjustment Steps
Distance Setting (Teaching)
Select the most appropriate teaching method in reference to the following descriptions.
La: Distance equivalent to threshold (a)
Lb: Distance equivalent to threshold (b)
The following settings are also possible:
Setting the maximum sensing distance of the sensor: Maximum distance setting.
Setting the minimum differential travel of the sensor: Minimum distance setting.
Distance from sensor to background must not exceed the values shown below during
normal one-point or zone one-point teaching.
Output ON range
Output ON range
Setting method
1
2
3
4
Set threshold
Application
Teaching
Install, wire, and turn on the sensor.
Perform distance setting (teaching). Refer to Distance Setting (Teaching) below.
Make a fine adjustment of the threshold, if necessary.
Refer to Manual Teaching (Fine Distance Setting)
Check that the mode selector is set to RUN.
1
Threshold (a) is set immediately in
front of the background.
The output is ON between the
sensor and La.
1
$
ON
Teaching without sensing
objects (i.e., Teaching the
background).
Press the TEACH button with
the background object.
present.
Normal one-point teaching
Background
E3G-L
Sensor
Threshold a (La)
Background
2
Threshold (a) is set approximately
in the middle between the
background and target object.
The output is ON between the
sensor and La.
2
$
$
ON
Detection of slight differences
in surface level.
Setting a threshold in the
middle between the
background and sensing object
for operation.
Background
Press the TEACH button with
the background object and
with the target object.
Normal two-point teaching
Maximum sensing distance of E3G-L3 type may differ by color of the target object
when setting distance is more than 150 mm (5.91 in).
Confirm the operation of the sensor before actual operation.
10
Sensor
Object
Object
Part number
E3G-L
E3G-L1j
E3G-L3j
Threshold a (La)
Background
Background
Sensor
Object
Distance from sensor to background
3
3
A pair of thresholds, (a) and (b),
are set.
The output is ON between La and
Lb.
D-ON L-ON
$
OFF
ON
ON
Detection of glossy objects in
front of the background.
32 mm (1.26 in) min.
55 mm (2.17 in) min.
Press the TEACH button with
the background object
(conveyor, etc.).
OFF
ON
OFF
Zone one-point teaching
Background
Sensor
E3G-L1/L3
E3G-L
Threshold a (La)
Background
Threshold b (Lb)