Specifications of E3G-L35

Features
Light ON / Dark ON
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
- 25 C
Operating Supply Voltage
10 V to 30 V
Sensing Distance
50 mm
Output Configuration
NPN
Sensing Method
Reflective, Diffuse
Sensing Object
Black Paper, Kodak® White Paper
Sensing Light
Infrared
Mounting Type
Bracket Mount
Current - Supply
65mA
Voltage - Supply
10 V ~ 30 V
Package / Case
Module, Connector
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
E3G-L1/L3
J ADJUSTMENTS (CONT.)
Normal One-point Teaching
La: Distance equivalent to threshold (a)
Application Example 1
Application Example 2
Procedure
1
2
3
4
5
1
2
3
4
5
6
1
2
3
4
5
6
Background
Adjusting the sensor differential travel to the minimum distance.
Setting the sensor to the maximum distance.
Set the mode selector to TEACH.
Set the NORMAL/ZONE mode selector to NORMAL.
Press the SET button with the background. The threshold
indicator (red) will turn ON.
Set the mode selector to RUN.
Set to L-ON or D-ON mode with the operation mode selector.
Set the mode selector to TEACH.
Set the NORMAL/ZONE mode selector to NORMAL.
Set the UP/DOWN selector to down.
Press the SET button for 3 s or more. The threshold indicator
(red) will turn ON.
The distance indicator (green) will turn ON. This means that
teaching is successful. Set the mode selector to RUN to
complete the teaching operation.
Set to L-ON or D-ON mode with the operation mode selector.
Set the mode selector to TEACH.
Set the NORMAL/ZONE mode selector to NORMAL.
Set the UP/DOWN selector to up.
Press the SET button for 3 s or more. The threshold indicator
(red) will turn ON.
The distance indicator (green) will turn ON. This means that
teaching is successful. Set the mode selector to RUN to
complete the teaching operation.
Set to L-ON or D-ON mode with the operation mode selector.
L-ON: Output ON between background and sensor.
D-ON: Output OFF between background and sensor.
Sensor
Operation
11
OUT
OUT
OUT
NEAR
Threshold indicator
(red) turns ON.
NEAR
NEAR
FAR
FAR
Threshold indicator
Threshold indicator
(red) turns ON.
FAR
FAR
Press
Press
Press
SET
SET
SET
SET
SET
NORM L
ZONE D
NORM L
NORM L
NORM L
TEACH
RUN
ZONE D
ZONE D
RUN
TEACH
TEACH
TEACH
RUN
ADJ
ADJ
ADJ
ADJ
Press the SET
button for 3 s
button for 3 s
or more.
Press the SET
button for 3 s
button for 3 s
or more.
Panel status
ON
Distance indicator
(green) turns ON.
Distance indicator
Distance indicator
(green) turns ON.
Threshold indicator
(red) turns ON.
(red) turns ON.
Set the mode
selector to
selector to
RUN.
Set the
mode selec-
mode selec-
tor to RUN.
E3G-L
E3G-L1/L3
Threshold a (La)
Background

Related parts for E3G-L35