E3G-L35 Omron, E3G-L35 Datasheet - Page 11

Photoelectric Sensors - Industrial CONVERGENT 200mm NPN CONN.

E3G-L35

Manufacturer Part Number
E3G-L35
Description
Photoelectric Sensors - Industrial CONVERGENT 200mm NPN CONN.
Manufacturer
Omron
Type
Photoelectric Sensorr
Series
E3Gr
Datasheet

Specifications of E3G-L35

Features
Light ON / Dark ON
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
- 25 C
Operating Supply Voltage
10 V to 30 V
Sensing Distance
50 mm
Output Configuration
NPN
Sensing Method
Reflective, Diffuse
Sensing Object
Black Paper, Kodak® White Paper
Sensing Light
Infrared
Mounting Type
Bracket Mount
Current - Supply
65mA
Voltage - Supply
10 V ~ 30 V
Package / Case
Module, Connector
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
E3G-L1/L3
J ADJUSTMENTS (CONT.)
Normal Two-point Teaching
La: Distance equivalent to threshold (a)
La: Distance equivalent to threshold (a)
J ADJUSTMENTS (CONT.)
Zone One-point Teaching
Procedure
Procedure
Background
Background
1
2
3
4
5
6
1
2
3
4
5
Sensor
Sensor
Set the mode selector to TEACH.
Set the NORMAL/ZONE mode selector to NORMAL.
Press the SET button with a sensing object located at sensing
position.
The threshold indicator (red) will turn ON.
Move the sensing object and press the SET button with the
background.
If the teaching is successful, the distance indicator (green) will
turn ON.
If the teaching is not successful, the threshold indicator (red) will
start to flash.
If the teaching is successful, set the mode selector to RUN to
complete the teaching operation.
If the teaching is not successful, change the position of the object
and setting distance that have been set and repeat the procedure
from step 3 above.
Set to L-ON or D-ON mode with the operation mode selector.
Set the mode selector to TEACH.
Set the NORMAL/ZONE mode selector to ZONE.
Press the SET button with the background.
All threshold indicators (Red) will turn ON while the SET button is
pressed. When the SET button is released:
$ If the teaching is successful, the distance indicator (green) will
$ If the teaching is not successful, the threshold indicator (red) will
Set the mode selector to RUN.
Set to L-ON or D-ON mode with the operation mode selector.
turn ON.
start to flash.
L-ON: Output ON with the background.
D-ON: Output OFF with the background.
Background
Sensor
Object
Operation
Operation
12
Background
Object
OUT
OUT
OUT
NEAR
NEAR
NEAR
FAR
FAR
FAR
FAR
FAR
Press
Press
P
Press
SET
SET
SET
NORM L
NORM L
NORM L
ZONE D
ZONE D
ZONE D
TEACH
RUN
TEACH
RUN
TEACH
RUN
ADJ
ADJ
ADJ
OFF
OFF
ON
ON
OK
OK
NG
NG
Panel status
Panel status
Threshold indicator
(red) turns ON.
Distance indicator
(green) turns ON.
(green) turns ON.
Threshold indicator
(red) starts to flash.
E3G-L
Object
Distance indicator
(green) turns ON.
Threshold indicator
(red) starts to flash.
E3G-L
Threshold a (La)
Background
Threshold b (Lb)
Threshold a (La)
Background
E3G-L1/L3

Related parts for E3G-L35