3-4-2
74
Initializing Memory
Initialization by Using the DIP Switch (Forced Initialization)
Operation 1. Set DIP SW2-1 on the NT20S to ON and turn the power ON or reset the
Reference: S Selecting “No” will cancel the memory initialization. In either case, when chang-
Note:
Be sure to turn the power OFF before setting the NT20S DIP switch.
Set the DIP switch as follows to initialize the screen data memory.
2. Turn the NT20S power to OFF.
3. Set NT20S DIP SW2-1 to OFF and turn the power ON.
S The NT20S DIP SW2-1 is used to set “Screen data forced initialize Yes/No”. Set-
Yes
No
ing the system settings or registering screen data, display the system menu after
setting DIP switch SW2-1 to the OFF position while the NT20S power is OFF,
then switching the power back ON.
ting this to Yes selects “effective”, and No “ineffective”.
Initialized the
NT20S.
Turn OFF the DIP Switch 2-1
and push the Reset Switch,
then return to RUN mode.
Initialize Screen Memory?
Screen Data Memory.
Select “Yes”.
The screen data memory is ini-
tialized. During the initialization,
the “Initializing” message will be
displayed.
Section 3-4