AN14BN0A3E032 EATON CUTLER HAMMER, AN14BN0A3E032 Datasheet - Page 8

Controller Starter

AN14BN0A3E032

Manufacturer Part Number
AN14BN0A3E032
Description
Controller Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of AN14BN0A3E032

No. Of Phases
Three
Current Rating
18A
Operating Temperature Range
-20°C To +65°C
External Width
1.75"
Current Min (full Load)
6.4A
Supply Voltage Max
120V
External Depth
3.49"
Mounting Type
DIN Rail
March 2009
Product Selection
When Ordering Supply
Table 33-99. Type AN16/AN56 NEMA — Manual or Automatic Reset Overload Relay — Non-reversing and Reversing
Note: Starter Catalog Numbers do not include heater packs. Select one carton of three heater packs. Heater pack selection,
CA08102001E
NEMA
Size
00
0
1
2
3
4
5
6
7
8
Underscore (_) indicates coil suffix required, see Table 33-100.
Maximum horsepower rating of starters for 380V 50 Hz applications:
The service-limit current ratings represent the maximum rms current, in amperes, which the controller shall be permitted to carry for protracted periods
in normal service. At service-limit current ratings, temperature rises shall be permitted to exceed those obtained by testing the controller at its
continuous current rating. The current rating of overload relays or trip current of other motor protective devices used shall not exceed the service-limit
current rating of the controller.
Common control. For separate 120V control, insert letter D in 7th position of listed Catalog Number. EXAMPLE: AN56VND0CB.
Catalog Number
Heater pack number (see selection
table, Pages 33-107 – 33-108) or full load
current.
NEMA Size
Horsepower
Continuous
Ampere
Rating
1215
NEMA Size 0
Cat. No. AN56BN0AC
135
270
540
810
18
27
45
90
9
Service-Limit
Current
Rating
(Amperes)
1400
104
156
311
621
932
11
21
32
52
00
1-1/2
0
5
Maximum UL Horsepower
1-Phase
115V 230V 208V
1
2
3
1/3
1
10
1
2
3
7-1/2
2
25
Magnet Coils — AC or DC
Starter coils listed in this section also
have a 50 Hz rating as shown in the
adjacent table. Select required starter
by Catalog Number and replace the
magnet coil alpha designation in the
Catalog Number (_) with the proper
Code Suffix from the adjacent table.
For Sizes 00 – 2 and 5 – 8, the magnet
coil alpha designation will be the next
to last digit of the listed Catalog Num-
ber. EXAMPLE: For a 380V, 50 Hz coil,
change AN16BN0_C to AN16BN0LC.
For all other sizes, the magnet coil
alpha designation will be the last digit
of the listed Catalog Number.
For DC Magnet Coils, see Accessories,
Pages 33-88 – 33-89.
3-Phase
150
200
400
3
50
25
40
75
10
For more information visit: www.eaton.com
1-1/2
3
7-1/2
NEMA Contactors & Starters
Freedom
Starters — 3-Phase Non-reversing and Reversing, Full Voltage, Bi-Metallic Overload
4
75
240V
100
200
300
450
15
30
50
1-1/2
3
7-1/2
5
150
Size 0
Non-reversing
Starter
480V 600V Catalog
100
200
400
600
900
10
25
50
2
5
6
300
100
200
400
600
900
10
25
50
2
5
7
600
3-Pole
Non-reversing
Number
AN16AN0_C
AN16BN0_C
AN16DN0_B
AN16GN0_B
AN16KN0_
AN16NN0_
AN16SN0_B
AN16TN0_C
AN16UN0_B
AN16VN0_B
8
900
Size 1
Reversing
Starter
Price
U.S. $
Table 33-100. AC Suffix Code
Technical Data. . . . . . . . . . Pages 33-79 – 33-81
Overload Relay . . . . . . . . . Page 33-103
Dimensions . . . . . . . . . . . . Pages 33-96 – 33-98
Special Modifications . . . Page 33-90
Accessories . . . . . . . . . . . . Pages 33-82 – 33-90
Heater Packs . . . . . . . . . . . Pages 33-107
Discount Symbol . . . . . . . . 1CD1
Coil Volts and Hertz
120/60 or 110/50
240/60 or 220/50
480/60 or 440/50
600/60 or 550/50
208/60
277/60
208 – 240/60
240/50
380 – 415/50
550/50
24/60, 24/50
24/50
32/50
48/60
48/50
NEMA Sizes 00 and 0 only.
NEMA Sizes 00 and 0 only. Sizes 1 – 8 are
24/60 only.
3-Pole
Reversing
Catalog
Number
AN56AN0_C
AN56BN0_C
AN56DN0_B
AN56GN0_B
AN56KN0_
AN56NN0_
AN56SN0_B
AN56TN0_C
AN56UN0_B
AN56VN0_B
Pages 33-107
Vertical
Reversing
Catalog
Number
AN56BNV0_
AN56DNV0_
AN56GNV0_
AN56KNV0_
AN56NNV0_
Code Suffix
A
B
C
D
E
H
J
K
L
N
T
U
V
W
Y
Size 3
Vertical
Reversing
Starter
33-108
Price
U.S. $
33-108
.
33-75
33

Related parts for AN14BN0A3E032