AN14BN0A3E032 EATON CUTLER HAMMER, AN14BN0A3E032 Datasheet

Controller Starter

AN14BN0A3E032

Manufacturer Part Number
AN14BN0A3E032
Description
Controller Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of AN14BN0A3E032

No. Of Phases
Three
Current Rating
18A
Operating Temperature Range
-20°C To +65°C
External Width
1.75"
Current Min (full Load)
6.4A
Supply Voltage Max
120V
External Depth
3.49"
Mounting Type
DIN Rail
33
33-68
Product Description
Freedom Series starters and contactors
feature a compact, space-saving design,
using state-of-the-art technology and
the latest in high strength, impact and
temperature resistant insulating
materials.
Features
Freedom NEMA
Adjustable Bimetallic Ambient
Compensated Overload relays with
interchangeable heater packs —
available in three basic sizes,
covering applications up to 900 hp
— reducing the number of different
contactor/overload relay combina-
tions that have to be stocked. Fixed
heater overloads are optional.
Electronic Solid-State Overload
Relay (C396) available as a stand-
alone unit and assembled with
Freedom Contactor.
A full line of snap-on accessories
common to both IEC and NEMA
devices — top and side mounted
auxiliary contacts, solid-state and
pneumatic timers, etc.
NEMA Contactors & Starters
Freedom
Product Family Overview
NEMA Size 1 Contactor
NEMA AN16DN0AB
NEMA Size 1 Starter
For more information visit: www.eaton.com
Straight-through wiring — line lugs
at top, load lugs at bottom.
Horizontal or vertical mounting
on upright panel for application
freedom.
Screw type power terminals have
captive, backed-out self-lifting pres-
sure plates with ± screws — reduced
wiring time.
Accessible terminals for easy wir-
ing. Optional fingerproof shields
available to prevent electrical shock.
Top located coil terminals conve-
nient and readily accessible. 45 mm
contactor magnet coils have three
terminals, permitting either top or
diagonal wiring — easy to replace
European or U.S. style starters
or contactors without changing
wiring layout.
Encapsulated dual voltage/
frequency magnet coils —
permanently marked with voltage,
frequency and part number. NEMA
Sizes 00 – 0 have non-encapsulated
coils as standard.
Designed to meet or exceed NEMA,
UL, CSA, VDE, BS and other interna-
tional standards and listings.
American engineering — built by
Eaton, using the latest in statistical
process control methods to produce
high quality, reliable products.
Sized based on standard NEMA
classifications.
Easy coil change and inspectable/
replaceable contacts.
Available in Open and NEMA Type
1, 3R, 4/4X and 12 enclosures.
Series B1 32A Overload
Standards and Certifications
ISO 9000 Certification
When you turn to Eaton’s Cutler-
Hammer Products, you turn to quality.
The International Standards Organiza-
tion (ISO) has established a series of
standards acknowledged by 91 indus-
trialized nations to bring harmony to
the international quest for quality. The
ISO certification process covers 20
quality system elements in design,
production and installation that must
conform to achieve registration. This
commitment to quality will result in
increased product reliability and total
customer satisfaction.
Short Circuit Protection
Fuses and Inverse-Time Circuit Breakers
may be selected per Article 430, Part D
of the National Electrical Code to pro-
tect motor branch circuits from fault
conditions. If higher ratings or settings
are required to start the motor, do not
exceed the maximum as listed in
Exception No. 2, Article 430-52.
Standard: Designed to meet or
exceed UL, NEMA, IEC, CSA, VDE
and BS.
UL listed: UL File #E1491, Guide
#NLDX — Open and NEMA 1, 4, 12
Enclosed
CSA Certified: CSA File #LR353,
Class #321104 Open and NEMA 1
Enclosed
C396 Electronic Overload
CA08102001E
March 2009

Related parts for AN14BN0A3E032

AN14BN0A3E032 Summary of contents

Page 1

... Top located coil terminals conve- nient and readily accessible contactor magnet coils have three terminals, permitting either top or diagonal wiring — easy to replace European or U.S. style starters or contactors without changing wiring layout. Encapsulated dual voltage/ frequency magnet coils — permanently marked with voltage, frequency and part number. NEMA Sizes 00 – ...

Page 2

... Uses panel-mount CT with C396A2A005SELAX Overload. Not required. NEMA Sizes 00 and 0 only. NEMA Sizes 00 and 0 only. Sizes 1 – 8 are 24/60 only. CA08102001E NEMA Contactors & Starters Freedom Catalog Number Selection Frame A — NEMA Size 00 P05 = 0.1 – 0.5A 002 = 0.4 – 2.0A 005 = 1.0 – ...

Page 3

... NEMA Contactors & Starters 33-70 Freedom Contactors — Non-reversing and Reversing Contents Description Product Family Overview Product Description . . . . . . . 33-68 33 Features . . . . . . . . . . . . . . . . 33-68 Standards and Certifications . . . . . . . . . . . 33-68 Catalog Number Selection . . . . . . . . . . . . . . 33-69 Contactors — Non-reversing and Reversing Product Description . . . . . . . 33-70 Features . . . . . . . . . . . . . . . . 33-70 Technical Data . . . . . . . . . . . 33-70 Product Selection — ...

Page 4

... Maximum horsepower rating of starters for 380V 50 Hz applications: NEMA Size Horsepower 1-1 Common control. For separate 120V control, insert letter D in 7th position of listed Catalog Number. EXAMPLE: CN15VND3C. Magnet Coils — AC and DC ...

Page 5

... NEMA Contactors & Starters 33-72 Freedom Contactors — Non-reversing and Reversing Product Selection — 2-, 4- and 5-Pole Contactors Table 33-94. Type CN15 NEMA Contactors — 2-, 4- and 5-Pole Non-reversing NEMA Continuous Maximum UL Horsepower Size Ampere 1-Phase (2-Pole) 33 Rating 115V 230V 00 9 1/3 ...

Page 6

... Special Modifications . . . . . . . 33-90 Renewal Parts . . . . . . . . . . . . 33-91 Dimensions . . . . . . . . . . . . . . . 33-94 CA08102001E NEMA Contactors & Starters Freedom Starters — 3-Phase Non-reversing and Reversing, Full Voltage NEMA Size 1 — Cat. No. AN16DN0AB Product Description Non-reversing Three-phase, full voltage magnetic starters are most commonly used to switch AC motor loads. Starters con- ...

Page 7

... NEMA Contactors & Starters 33-74 Freedom Starters — 3-Phase Non-reversing and Reversing, Full Voltage Technical Data Table 33-96. Wire (75°C) Sizes — AWG or kcmil — NEMA Sizes 00 – 2 — Open and Enclosed NEMA Size Wire Size Power Terminals — Line – ...

Page 8

... Note: Starter Catalog Numbers do not include heater packs. Select one carton of three heater packs. Heater pack selection, Underscore (_) indicates coil suffix required, see Table 33-100. Maximum horsepower rating of starters for 380V 50 Hz applications: NEMA Size Horsepower ...

Page 9

... Prices of starters do not include heater packs. Select 2 packs (2 overload relays, one for each speed). Heater pack selection, Pages 33-107 – 33-108. If branch circuit protective device is 45A or greater, C320FBR1 fuse kit(s) may be required for circuit protection per NEC 530-072. Table 33-103. Magnetic Coils — Coil Voltage and Hz Code Suffi ...

Page 10

... Note: Starter Catalog Numbers do not include heater packs. Select 1 carton of 3 heater packs. Heater pack selection, Pages 33-107 – 33-108. For separate 120V control circuit. For maximum hp at listed motor voltages, use the rating of other starters of same size. For more information visit: www.eaton.com 33-77 AC Lines “ ...

Page 11

... NEMA Contactors & Starters 33-78 Freedom Starters — 3-Phase Non-reversing and Reversing, Full Voltage, C396 Electronic Overload Product Selection 33 Catalog Number AN14GN0_ _ _ Table 33-105. Type AN14/AN54 NEMA — C396 Selectable Reset Electronic Overload Relay — Non-reversing and Reversing NEMA Cont. ...

Related keywords