AN14BN0A3E032 EATON CUTLER HAMMER, AN14BN0A3E032 Datasheet - Page 6

Controller Starter

AN14BN0A3E032

Manufacturer Part Number
AN14BN0A3E032
Description
Controller Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of AN14BN0A3E032

No. Of Phases
Three
Current Rating
18A
Operating Temperature Range
-20°C To +65°C
External Width
1.75"
Current Min (full Load)
6.4A
Supply Voltage Max
120V
External Depth
3.49"
Mounting Type
DIN Rail
March 2009
Contents
Description
Product Family Overview
Starters — 3-Phase Non-reversing
Starters — 3-Phase Multispeed,
Starters — Single-Phase
Starters — 3-Phase Non-reversing
Technical Data . . . . . . . . . . . . . 33-79
Accessories . . . . . . . . . . . . . . . 33-82
Special Modifications . . . . . . . 33-90
Renewal Parts . . . . . . . . . . . . 33-91
Dimensions . . . . . . . . . . . . . . . 33-94
CA08102001E
and Reversing, Full Voltage,
Bi-Metallic Overload
Bi-Metallic Overload
Non-reversing, Full Voltage,
Bi-Metallic Overload
and Reversing, Full Voltage,
C386 Electronic Overload . . 33-78
Product Description . . . . . . 33-68
Features . . . . . . . . . . . . . . . 33-68
Standards and
Catalog Number
Product Description . . . . . . 33-73
Features . . . . . . . . . . . . . . . 33-73
Technical Data . . . . . . . . . . 33-74
Wiring Diagrams . . . . . . . . 33-74
Product Selection . . . . . . . . 33-75
Product Selection . . . . . . . . 33-76
Product Description . . . . . . 33-77
Wiring Diagrams . . . . . . . . 33-77
Product Selection . . . . . . . . 33-77
Auxiliary Contacts . . . . . . . 33-86
DC Magnet Coils . . . . . . . . 33-88
Mounting Plates . . . . . . . . . 33-89
Certifications . . . . . . . . . . 33-68
Selection . . . . . . . . . . . . . 33-69
Page
Product Description
Non-reversing
Three-phase, full voltage magnetic
starters are most commonly used to
switch AC motor loads. Starters con-
sist of a magnetically actuated switch
(contactor) and an overload relay
assembled together.
Reversing
Three-phase, full voltage magnetic
starters are used primarily for revers-
ing of 3-phase squirrel cage motors.
They consist of two contactors and a
single overload relay assembled
together. The contactors are mechani-
cally and electrically interlocked to
prevent line shorts and energization
of both contactors simultaneously.
Features
For more information visit: www.eaton.com
Bimetallic Ambient Compensated
Overload relays — available in three
basic sizes covering applications up
to 900 hp — reducing number of
different contactor/overload relay
combinations that have to be
stocked.
These overload relays feature:
NEMA Size 1 — Cat. No. AN16DN0AB
NEMA Size 1 — Cat. No. AN56DN0AB
NEMA Contactors & Starters
Freedom
Starters — 3-Phase Non-reversing and Reversing, Full Voltage
Selectable Manual or Automatic
Reset operation.
Non-reversing
Reversing
The C396 is a self-powered, robust
electronic overload designed for
integrate use with Freedom NEMA
contactors.
Long life twin break, silver cadmium
oxide contacts — provide excellent
conductivity and superior resistance
to welding and arc erosion. Gener-
ously sized for low resistance and
cool operation.
Designed to 3,000,000 electrical
operations at maximum hp ratings
up through 25 hp at 600V.
Steel mounting plate standard on all
open type starters.
Wired for separate or common
control.
Holding circuit contact(s) supplied
as standard:
Each contactor (Size 00 – 8)
supplied with one NO-NC side
mounted contact block as standard.
NC contacts are wired as electrical
interlocks.
Interchangeable heater packs
adjustable ±24% to match motor
FLA and calibrated for 1.0 and
1.15 service factors. Heater packs
for smaller overload relay will
mount in larger overload relay —
useful in derating applications
such as jogging.
Load lugs built into relay base.
Single-phase protection, Class 20
or Class 10 trip time.
Overload trip indication.
Electrically isolated NO-NC con-
tacts (pull RESET button to test).
Tiered feature set to provide cov-
erage specific to your application.
Broad 5:1 FLA range for maxi-
mum flexibility.
Coverage from 0.05 – 1500 Amps
to meet all your needs.
Sizes 00 – 3 have a NO auxiliary
contact block mounted on right-
hand side (on Size 00, contact
occupies 4th power pole position
— no increase in width).
Sizes 4 – 5 have a NO contact
block mounted on left side.
Sizes 6 – 7 have a 2NO/2NC
contact block on top left.
Size 8 has a NO/NC contact block
on top left back and a NO on top
right back.
33-73
33

Related parts for AN14BN0A3E032