AN14BN0A3E032 EATON CUTLER HAMMER, AN14BN0A3E032 Datasheet - Page 7

Controller Starter

AN14BN0A3E032

Manufacturer Part Number
AN14BN0A3E032
Description
Controller Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of AN14BN0A3E032

No. Of Phases
Three
Current Rating
18A
Operating Temperature Range
-20°C To +65°C
External Width
1.75"
Current Min (full Load)
6.4A
Supply Voltage Max
120V
External Depth
3.49"
Mounting Type
DIN Rail
33
33-74
Technical Data
Table 33-96. Wire (75°C) Sizes — AWG or kcmil — NEMA Sizes 00 – 2 — Open and Enclosed
Power Terminals — Line
Power Terminals — Load — Cu Only (stranded or solid)
Control Terminals — Cu Only
Table 33-97. Wire (75°C) Sizes — AWG or kcmil — NEMA Sizes 3 – 8 — Open and Enclosed
Power Terminals — Line and Load
Control Terminals — Cu Only
Wiring Diagrams
Figure 33-24. Typical Wiring Diagrams — Three-Phase and Single-Phase Applications
NEMA Size
00
0
1
2
00 – 0
1 – 2
12 – 16 AWG stranded, 12 – 14 AWG solid
NEMA Size
3
4
5
6
7
8
12 – 16 AWG stranded, 12 – 14 AWG solid
Separate Control
Remove Wire “c”
when it is supplied.
Connect separate
control lines to the
No. 1 Terminal on
the remote pilot
device and Terminal
96 on the overload
relay.
Separate Control
Remove Wire “c”
when it is supplied.
Connect separate
control lines to the
No. 1 Terminal on
the remote pilot
device and Terminal
96 on the overload
relay.
Two compartment box lug.
Minimum per NEC. Maximum wire size: Sizes 00 and 0 to 8 AWG and Sizes 1 – 2 to 2 AWG.
Minimum per NEC. Maximum wire size: Sizes 00 and 0 to 8 AWG and Sizes 1 – 2 to 2 AWG.
NEMA Contactors & Starters
Freedom
Starters — 3-Phase Non-reversing and Reversing, Full Voltage
1
1
T1 T2
L1 L2
L1 L2 L3
T1 T2 T3
A1 A2
T1 T2 T3
T1 T2 T3
Motor
Motor
A1 A2
“c”
A2
Wire Size
12 – 16 AWG stranded, 12 – 14 AWG solid
14 – 6 AWG stranded or solid
14 – 2 AWG stranded or solid
Wire Size
1/0 – 14 AWG Cu/Al
Open — 3/0 – 8 AWG Cu; Enclosed — 250 kcmil — 6 AWG Cu/Al
750 kcmil — 2 AWG; or (2) 250 kcmil — 3/0 AWG Cu/Al
(2) 750 kcmil — 3/0 AWG Cu/Al
(3) 750 kcmil — 3/0 AWG Cu/Al
(4) 750 kcmil — 1/0 AWG Cu/Al
L3
T3
8 – 16 AWG stranded, 10 – 14 AWG solid
8 – 14 AWG stranded or solid
3 – 14 AWG (upper) and/or 6 – 14 AWG (lower) stranded or solid
“c”
98
97
96
95
98
97
96
95
2
3
NEMA Sizes 0, 1 and 2
2
3
When more than
“A” and connect
When more than
“A” and connect
one pushbutton
one pushbutton
omit Connector
omit Connector
station is used,
station is used,
NEMA Size 00
per sketch.
per sketch.
Cu Only
Auto Reset OL Relays
Auto Reset OL Relays
Remote Pilot Devices
Remote Pilot Devices
Control
Control
Control
Control
3 Wire
3 Wire
2 Wire
2 Wire
Not for Use with
Not for Use with
For more information visit: www.eaton.com
1
1
Start
Stop
Start
Stop
Start
Stop
Start
Stop
“A”
“A”
3
3
2
1
3
3
2
1
Start
Start
Stop
Stop
3
2
1
3
2
1
Dotted Connections
Dotted Connections
T1
L1
Field Conversion
Field Conversion
to 1-Phase, Add
to 1-Phase, Add
L1
T1
L2
T1
T1
Motor
Motor
L2
T2
T2
T2
T2
Table 33-98. Plugging and Jogging Service
Horsepower Ratings
Kits and Accessories
Renewal Parts Publication
Numbers
NEMA
Size
00
0
1
2
3
4
5
6
Maximum horsepower where operation is
interrupted more than 5 times per minute, or
more than 10 times in a 10 minute period.
NEMA Standard ICS2-1993 table 2-4-3.
Auxiliary Contacts, contactor
mounted — Pages 33-86 – 33-87.
Transient Suppressor, for magnet
coil — Pages 33-84.
Timers — Solid-State and
Pneumatic, mount on contactor —
Page 33-83.
See Page 33-91.
200V
125
15
25
60
1-1/2
3
7-1/2
230V
150
10
20
30
75
1-1/2
3
1/2
150
300
460V
15
30
60
2
5
1/2
CA08102001E
March 2009
575V
150
300
15
30
60
2
5
1/2

Related parts for AN14BN0A3E032