AN14BN0A3E032

Manufacturer Part Number
AN14BN0A3E032
Description
Controller Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of AN14BN0A3E032

No. Of Phases
Three
Current Rating
18A
Operating Temperature Range
-20°C To +65°C
External Width
1.75"
Current Min (full Load)
6.4A
Supply Voltage Max
120V
External Depth
3.49"
Mounting Type
DIN Rail
33
33-70
Contents
Description
Product Family Overview
Contactors — Non-reversing
Technical Data. . . . . . . . . . . . . . 33-79
Accessories . . . . . . . . . . . . . . . . 33-82
Special Modifications. . . . . . . . 33-90
Renewal Parts . . . . . . . . . . . . . 33-91
Dimensions . . . . . . . . . . . . . . . . 33-94
Product Description
Non-reversing
Contactors are most commonly used
to switch motor loads in applications
where running overcurrent protection
is either not required or is provided
separately. Contactors consist of a
magnetically actuated switch which
can be remotely operated by a push-
button station or pilot device such as
a proximity switch, limit switch, float
switch, auxiliary contacts, etc.
and Reversing
NEMA Size 1 — Cat. No. CN15DN3AB
Product Description . . . . . . . 33-68
Features . . . . . . . . . . . . . . . . 33-68
Standards and
Catalog Number
Product Description . . . . . . . 33-70
Features . . . . . . . . . . . . . . . . 33-70
Technical Data . . . . . . . . . . . 33-70
Product Selection —
Product Selection —
Auxiliary Contacts . . . . . . . . 33-86
DC Magnet Coils . . . . . . . . . 33-88
Mounting Plates. . . . . . . . . . 33-89
NEMA Contactors & Starters
Freedom
Contactors — Non-reversing and Reversing
Certifications . . . . . . . . . . . 33-68
Selection . . . . . . . . . . . . . . 33-69
3-Pole Contactors . . . . . . . 33-71
2-, 4- and 5-Pole
Contactors . . . . . . . . . . . . . 33-72
Page
Reversing
Reversing contactors are used prima-
rily for reversing single- or three-phase
motors in applications where running
overcurrent protection is either not
required or is provided separately.
They consist of two contactors
mechanically and electrically inter-
locked to prevent line shorts and
energization of both contactors
simultaneously.
Features
Non-reversing
Reversing
For more information visit: www.eaton.com
Designed specifically for use in
applications requiring NEMA rat-
ings. Contactors meet or exceed
NEMA standards ICS 2-1993.
Long life twin break, silver cadmium
oxide contacts — provide excellent
conductivity and superior resistance
to welding and arc erosion.
Designed to 3,000,000 electrical
operations at maximum hp ratings
up through 25 hp at 600V.
Steel mounting plate standard on all
open type contactors.
Holding circuit contact(s) supplied
as standard:
One NO-NC side mounted interlock
supplied as standard on each con-
tactor for Sizes 00 – 8.
Sizes 00 – 3 have NO auxiliary
contact block mounted on right
hand side (on Size 00, contact
occupies 4th power pole position
— no increase in width).
Sizes 4 – 5 have a NO contact
block mounted on left side.
Sizes 6 – 7 have a 2NO/2NC
contact block on top left.
Size 8 has a NO/NC contact block
on top left back and a NO contact
block on top right back.
NEMA Size 1
Cat. No. CN55DN3AB
Technical Data
Table 33-90. Wire (75°C) Sizes — AWG or
kcmil — Open and Enclosed
Table 33-91. Plugging and Jogging Service
Horsepower Ratings
Kits and Accessories
Renewal Parts Publication
Numbers
NEMA
Size
00
0
1
2
3
4
5
6
7
8
NEMA
Size
00
0
1
2
3
4
5
6
Two compartment box lug.
Maximum horsepower where operation is
interrupted more than 5 times per minute or
more than 10 times in a 10 minute period.
NEMA standard ICS 2-1993 table 2-4-3.
Auxiliary Contacts, contactor
mounted — Pages 33-86 and 33-87.
Transient Suppressor, for magnet
coil — Pages 33-84.
Timers — Solid-State and
Pneumatic, mount on contactor —
Page 33-83.
See Page 33-91.
Power Terminals
Line or Load
12 – 16 stranded;
12 – 14 solid Cu
10 – 14 solid Cu
8 – 14 stranded or
solid Cu
3 – 14 (upper) and/or
6 – 14 (lower) stranded
or solid
1/0 – 14 Cu/Al
250 mcm – 6
750 kcmil – 2, or
(2) 250 kcmil – 3/0 Cu/Al
(2) 750 kcmil – 3/0 Cu/Al
(3) 750 kcmil – 3/0 Cu/Al
(4) 750 kcmil – 4/0 Cu/Al
200V
125
8 – 16 stranded;
15
25
60
1-1/2
3
7-1/2
Cu
230V
150
10
20
30
75
1-1/2
3
1/2
150
300
460V
15
30
60
2
5
1/2
CA08102001E
Control
Terminals
Cu Only
12 – 16
12 – 14
March 2009
stranded
solid
575V
150
300
15
30
60
2
5
1/2