CS5501-BS Cirrus Logic Inc, CS5501-BS Datasheet - Page 32

no-image

CS5501-BS

Manufacturer Part Number
CS5501-BS
Description
A/D Converter (A-D) IC
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS5501-BS

Peak Reflow Compatible (260 C)
No
No. Of Bits
16 Bit
Leaded Process Compatible
No
Mounting Type
Surface Mount
Interface Type
Serial
Package / Case
20-SOIC
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS5501-BS
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
CS5501-BSZ
Manufacturer:
CIRRUS
Quantity:
20 000
SPECIFICATION DEFINITIONS
Linearity Error
Differential Linearity
Full-Scale Error
Unipolar Offset
Bipolar Offset
Bipolar Negative Full-Scale Error
Positive Full-Scale Input Overrange
Negative Full-Scale Input Overrange
Offset Calibration Range
Input Span
32
The deviation of a code from a straight line which connects the two endpoints of the A/D
Converter transfer function. One endpoint is located 1/2 LSB below the first code transition
and the other endpoint is located 1/2 LSB beyond the code transition to all ones. Units in
percent of full-scale.
The deviation of a code’s width from the ideal width. Units in LSB’s.
The deviation of the last code transition from the ideal (VREF-3/2 LSB’s). Units in LSBs.
The deviation of the first code transition from the ideal (1/2 LSB above AGND) when in
unipolar mode (BP/UP low). Units in LSBs.
The deviation of the mid-scale transition (011...111 to 100...000) from the ideal (1/2 LSB
below AGND) when in bipolar mode (BP/UP high). Units in LSBs.
The deviation of the first code transition from the ideal when in bipolar mode (BP/UP high).
The Ideal is defined as lying on a straight line which passes through the final and mid-scale
code transitions. Units in LSBs.
The absolute maximum positive voltage allowed for either accurate system calibration or
accurate conversions. Units in volts.
The absolute maximum negative voltage allowed for either accurate system calibration or
accurate conversions. Units in volts.
The CS5501/CS5503 calibrate their offset to the voltage applied to the AIN pin when in system
calibration mode. The first code transition defines Unipolar Offset when BP/UP is low and the
mid-scale transition defines Bipolar Offset when BP/UP is high. The Offset Calibration Range
specification indicates the range of voltages applied to AIN that the CS5501 or CS5503 can
accept and still calibrate offset accurately. Units in volts.
The voltages applied to the AIN pin in system-calibration schemes define the CS5501/CS5503
analog input range. The Input Span specification indicates the minimum and maximum input
spans from zero-scale to full-scale in unipolar, or from positive full scale to negative full scale
in bipolar, that the CS5501/CS5503 can accept and still calibrate gain accurately. Units in
volts.
CS5501/CS5503
DS31F2

Related parts for CS5501-BS