W25Q64CVSSIG Winbond Electronics, W25Q64CVSSIG Datasheet - Page 46

no-image

W25Q64CVSSIG

Manufacturer Part Number
W25Q64CVSSIG
Description
IC SPI FLASH 64MBIT 8-SOIC
Manufacturer
Winbond Electronics
Datasheet

Specifications of W25Q64CVSSIG

Format - Memory
FLASH
Memory Type
FLASH
Memory Size
64M (8M x 8)
Speed
80MHz
Interface
SPI Serial
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
8-SOIC (0.083", 2.10mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q5822008

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W25Q64CVSSIG
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Company:
Part Number:
W25Q64CVSSIG
Quantity:
15
W25Q64CV
11.2.27 Erase / Program Suspend (75h)
The Erase/Program Suspend instruction “75h”, allows the system to interrupt a Sector or Block Erase
operation or a Page Program operation and then read from or program/erase data to, any other sectors
or blocks. The Erase/Program Suspend instruction sequence is shown in figure 25.
The Write Status Register instruction (01h) and Erase instructions (20h, 52h, D8h, C7h, 60h, 44h) are not
allowed during Erase Suspend. Erase Suspend is valid only during the Sector or Block erase operation. If
written during the Chip Erase operation, the Erase Suspend instruction is ignored. The Write Status
Register instruction (01h) and Program instructions (02h, 32h, 42h) are not allowed during Program
Suspend. Program Suspend is valid only during the Page Program or Quad Page Program operation.
The Erase/Program Suspend instruction “75h” will be accepted by the device only if the SUS bit in the
Status Register equals to 0 and the BUSY bit equals to 1 while a Sector or Block Erase or a Page
Program operation is on-going. If the SUS bit equals to 1 or the BUSY bit equals to 0, the Suspend
instruction will be ignored by the device. A maximum of time of “t
” (See AC Characteristics) is required
SUS
to suspend the erase or program operation. The BUSY bit in the Status Register will be cleared from 1 to
0 within “t
” and the SUS bit in the Status Register will be set from 0 to 1 immediately after
SUS
Erase/Program Suspend. For a previously resumed Erase/Program operation, it is also required that the
Suspend instruction “75h” is not issued earlier than a minimum of time of “t
” following the preceding
SUS
Resume instruction “7Ah”.
Unexpected power off during the Erase/Program suspend state will reset the device and release the
suspend state. SUS bit in the Status Register will also reset to 0. The data within the page, sector or
block that was being suspended may become corrupted. It is recommended for the user to implement
system design techniques against the accidental power interruption and preserve data integrity during
erase/program suspend state.
Figure 25. Erase/Program Suspend Instruction Sequence
- 46 -