AT86RF401U-XI Atmel, AT86RF401U-XI Datasheet - Page 10

IC MICRO TX RF W/AVR 20-TSSOP

AT86RF401U-XI

Manufacturer Part Number
AT86RF401U-XI
Description
IC MICRO TX RF W/AVR 20-TSSOP
Manufacturer
Atmel
Datasheet

Specifications of AT86RF401U-XI

Frequency
264MHz ~ 456MHz
Applications
Garage Opener, RKE, Telemetry
Modulation Or Protocol
ASK, OOK
Data Rate - Maximum
10 kbps
Power - Output
6dBm
Current - Transmitting
23.2mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Memory Size
2KB Flash, 128 Byte EEPROM, 128Byte SRAM
Voltage - Supply
2 V ~ 5 V
Operating Temperature
-40°C ~ 85°C
Package / Case
20-TSSOP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Features
-
Other names
AT86RF401U
Bandgap Reference
Brown-out Protection/Low
Battery Detection
Brown-out Protection
Low Battery Detection
10
AT86RF401
period. A number of registers are available to adjust the performance of the lock detec-
tor. These include lock delay and unlock delay timers as well as a cycle slip counter.
The device uses a 1.2V (nominal) bandgap reference generator to provide consistent
performance over a wide range of input supply voltages. This reference voltage is used
throughout the device.
The brown-out protection and low battery detection functions consist of a voltage refer-
ence, a sampling block and an autozero comparator. The circuit’s primary operating
mode is brown-out protection.
The brown-out protection circuit detects when the level of V
voltage that guarantees proper operation. The brown-out voltage for this device is typi-
cally 1.8 volts.
If a brown-out occurs, the device enters a reset state. It stays in this state until either of
the following occurs:
The low battery detection feature allows the programmer to select a voltage threshold
(1.5–2.7 volts) for V
warning may be utilized to activate an I/O port or to change the transmitted message.
Additionally, the programmer has the option of defining the amount of hysteresis on this
threshold. More detail can be found in register descriptions for I/O Enable (IO_ENAB,
$30, page 39) and Battery Low Configuration (BL_CONFIG, $35, page 42).
The level of V
the device to enter a warm reboot state.
The level of V
the device into the “cold start” mode of operation, identical to battery insertion.
DD
DD
DD
increases ~0.1–0.2 volts above the brown-out voltage. This causes
drops to ~0 volts, then increases above the POR level. This places
at which a warning flag is issued to the user. For example, this
DD
drops below the minimum
1424F–RKE–12/03