SI4022-A1-FT Silicon Laboratories Inc, SI4022-A1-FT Datasheet - Page 16

no-image

SI4022-A1-FT

Manufacturer Part Number
SI4022-A1-FT
Description
IC TX FSK 915MHZ 3.8V 16-TSSOP
Manufacturer
Silicon Laboratories Inc
Type
ISM Band FSK Transmitterr
Datasheet

Specifications of SI4022-A1-FT

Package / Case
16-TSSOP
Frequency
868MHz, 915MHz
Applications
ISM
Modulation Or Protocol
FSK
Data Rate - Maximum
115.2kbps
Power - Output
6dBm
Current - Transmitting
24mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Voltage - Supply
2.2 V ~ 3.8 V
Operating Temperature
-40°C ~ 85°C
Operating Frequency
434 MHz to 915 MHz
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Operating Supply Voltage
2.5 V, 3.3 V
Supply Current
24 mA
Supply Voltage (max)
3.8 V
Supply Voltage (min)
2.2 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Memory Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
336-1623-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI4022-A1-FT
Manufacturer:
SILICON
Quantity:
470
Part Number:
SI4022-A1-FT
Manufacturer:
SILICONLABS/芯科
Quantity:
20 000
Company:
Part Number:
SI4022-A1-FT
Quantity:
500
MATCHING NETWORK FOR A 50 OHM SINGLE ENDED OUTPUT
Matching Network Schematic
RX-TX ALIGNMENT PROCEDURES
RX-TX frequency offset can be caused only by the differences in the actual reference frequency. To minimize these errors it is
suggested to use the same crystal type and the same PCB layout for the crystal placement on the RX and TX PCBs.
To verify the possible RX-TX offset it is suggested to measure the CLK output of both chips with a high level of accuracy. Do not
measure the output at the XTL pin since the measurement process itself will change the reference frequency. Since the carrier
frequencies are derived from the reference frequency, having identical reference frequencies and nominal frequency settings at the
TX and RX side there should be no offset if the CLK signals have identical frequencies.
It is possible to monitor the actual RX-TX offset using the AFC status report included in the status byte of the receiver. By reading out
the status byte from the receiver the actual measured offset frequency will be reported. In order to get accurate values the AFC has
to be disabled during the read by clearing the "en" bit in the AFC Control Command (bit 0).
C
1
L
L
, C
1
3
[nH]
[nH]
2
[pF]
100
3.9
6.8
to RFN
to RFP
VDD
L3
L1
C1
C2
GND
GND
50 Ohm
load
Si4022
16