TDA5250 Infineon Technologies, TDA5250 Datasheet - Page 70

TX/RX ASK/FSK 868-870MHZ 38TSSOP

TDA5250

Manufacturer Part Number
TDA5250
Description
TX/RX ASK/FSK 868-870MHZ 38TSSOP
Manufacturer
Infineon Technologies
Type
Transceiverr
Datasheets

Specifications of TDA5250

Package / Case
38-TSSOP
Frequency
868MHz
Data Rate - Maximum
64kbps
Modulation Or Protocol
ASK, FSK
Applications
RKE, Remote Control Systems
Power - Output
9dBm
Sensitivity
-109dBm
Voltage - Supply
2.1 V ~ 5.5 V
Current - Receiving
9mA
Current - Transmitting
12mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Operating Frequency
870 MHz
Operating Supply Voltage
2.5 V, 3.3 V, 5 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Product Depth (mm)
4.4mm
Product Length (mm)
9.7mm
Operating Supply Voltage (min)
2.1V
Operating Supply Voltage (max)
5.5V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Compliant
Other names
SP000012956
TDA5250
TDA5250INTR
TDA5250XT
TDA5250XT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TDA5250
Manufacturer:
Infineon Technologies
Quantity:
135
Part Number:
TDA5250
Quantity:
198
Part Number:
TDA5250D2
Manufacturer:
INFINEON
Quantity:
300
Part Number:
TDA5250D2
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
3.7.1
The high time of data is used to measure the frequency of the data signal. For Manchester coding
either the data frequency or half of the data frequency have to be detected corresponding to one
high time or twice the high time of data signal.
A time period of 3*2*T is necessary to decide about valid or invalid data.
Figure 3-33
Example to calculate the thresholds for a given data rate:
- Data signal manchester coded
- Data Rate: 2kbit//s
- f
Then the period equals to
respectively the high time is 0,25ms.
We set the thresholds to +-10% and get: T1= 0,225ms and T2= 0,275ms
The thresholds TH1 and TH2 are calculated with following formulas
Data Sheet
clk
= 18,0896 MHz
Frequency Window for Data Rate Detection
Window Counter timing
possible
possible
GATE 1
GATE 2
DATA
TH2
TH1
2
T
0
0
=
T2
T1
=
T
=
T2
2kbit/s
T1
0
0
1
f
f
2*T2
2*T1
clk
4
clk
2*T
4
70
=
1
1
0,5ms
[3 – 37]
[3 – 38]
0
[3 – 36]
t
t
t
TDA5250 D2
window_count_timing.wmf
Version 1.7
Application
2007-02-26

Related parts for TDA5250