C8051F353 Silicon Laboratories Inc, C8051F353 Datasheet - Page 160

IC 8051 MCU 8K FLASH 28MLP

C8051F353

Manufacturer Part Number
C8051F353
Description
IC 8051 MCU 8K FLASH 28MLP
Manufacturer
Silicon Laboratories Inc
Series
C8051F35xr
Datasheets

Specifications of C8051F353

Core Processor
8051
Core Size
8-Bit
Speed
50MHz
Connectivity
SMBus (2-Wire/I²C), SPI, UART/USART
Peripherals
POR, PWM, Temp Sensor, WDT
Number Of I /o
17
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
768 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x16b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
28-VQFN Exposed Pad, 28-HVQFN, 28-SQFN, 28-DHVQFN
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F353-GM
Manufacturer:
SiliconL
Quantity:
8 050
C8051F350/1/2/3
19.5.2. Master Receiver Mode
Serial data is received on SDA while the serial clock is output on SCL. The SMBus interface generates the
START condition and transmits the first byte containing the address of the target slave and the data direc-
tion bit. In this case the data direction bit (R/W) will be logic 1 (READ). Serial data is then received from the
slave on SDA while the SMBus outputs the serial clock. The slave transmits one or more bytes of serial
data. After each byte is received, ACKRQ is set to ‘1’ and an interrupt is generated. Software must write
the ACK bit (SMB0CN.1) to define the outgoing acknowledge value (Note: writing a ‘1’ to the ACK bit gen-
erates an ACK; writing a ‘0’ generates a NACK). Software should write a ‘0’ to the ACK bit after the last
byte is received, to transmit a NACK. The interface exits Master Receiver Mode after the STO bit is set and
a STOP is generated. Note that the interface will switch to Master Transmitter Mode if SMB0DAT is written
while an active Master Receiver. Figure 19.9 shows a typical Master Receiver sequence. Two received
data bytes are shown, though any number of bytes may be received. Notice that the ‘data byte transferred’
interrupts occur before the ACK cycle in this mode.
160
Interrupt
S
Figure 19.9. Typical Master Receiver Sequence
Received by SMBus
Interface
Transmitted by
SMBus Interface
SLA
R
Interrupt
A
Data Byte
Rev. 0.4
Interrupt
A
S = START
P = STOP
A = ACK
N = NACK
R = READ
SLA = Slave Address
Data Byte
Interrupt
N
P

Related parts for C8051F353