Specifications of W77E058A40DL

Program Memory Type
FLASH
Program Memory Size
32KB (32K x 8)
Core Processor
8051
Core Size
8-Bit
Speed
40MHz
Connectivity
EBI/EMI, Serial Port
Peripherals
POR, WDT
Number Of I /o
32
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
40-DIP
Cpu Family
W77
Device Core
8051
Device Core Size
8b
Frequency (max)
40MHz
Interface Type
UART
Total Internal Ram Size
1KB
# I/os (max)
32
Number Of Timers - General Purpose
3
Operating Supply Voltage (typ)
5V
Operating Supply Voltage (max)
5.5V
Operating Supply Voltage (min)
4.5V
Instruction Set Architecture
CISC
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Mounting
Through Hole
Pin Count
40
Package Type
PDIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W77E058A40DL
Manufacturer:
WINBOND
Quantity:
4 500
Part Number:
W77E058A40DL
Manufacturer:
WINBOND
Quantity:
5
Part Number:
W77E058A40DL
Manufacturer:
WSI
Quantity:
550
Part Number:
W77E058A40DL
Manufacturer:
WINBOND/华邦
Quantity:
20 000
instructions to reset the watchdog timer which will allow the code to run without any watchdog timer
interrupts. Now the watchdog timer reset is enabled and the watchdog interrupt may be disabled. If
any errant code is executed now, then the reset watchdog timer instructions will not be executed at the
required instants and watchdog reset will occur.
The watchdog time-out selection will result in different time-out values depending on the clock speed.
The reset, when enabled, will occur 512 clocks after the time-out has occurred.
Table 9. Time-out values for the watchdog timer
The Watchdog timer will de disabled by a power-on/fail reset. The Watchdog timer reset does not
disable the watchdog timer, but will restart it. In general, software should restart the timer to put it into
a known state.
The control bits that support the Watchdog timer are discussed below.
WD1
0
0
1
1
WD0
0
1
0
1
WATCHDOG
INTERVAL
2
2
2
2
17
20
23
26
NUMBER OF
67108864
CLOCKS
1048576
8388608
131072
- 61 -
36408.88 mS
4551.11 mS
@ 1.8432 MHZ
568.89 mS
71.11 mS
TIME
Publication Release Date: April 17, 2007
6710.89 mS
104.86 mS
838.86 mS
13.11 mS
@ 10 MHZ
TIME
W77E058A
2684.35 mS
335.54 mS
41.94 mS
5.24 mS
@ 25 MHZ
Revision A10