ATTINY2313A-MUR Atmel, ATTINY2313A-MUR Datasheet - Page 189

no-image

ATTINY2313A-MUR

Manufacturer Part Number
ATTINY2313A-MUR
Description
MCU AVR 2K FLASH 20MHZ 20QFN
Manufacturer
Atmel
Series
AVR® ATtinyr
Datasheet

Specifications of ATTINY2313A-MUR

Core Processor
AVR
Core Size
8-Bit
Speed
20MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
18
Program Memory Size
2KB (1K x 16)
Program Memory Type
FLASH
Eeprom Size
128 x 8
Ram Size
128 x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATTINY2313A-MUR
Manufacturer:
LT
Quantity:
4 439
20.6.11
20.6.12
20.6.13
8246A–AVR–11/09
Programming the Lock Bits
Reading the Fuse and Lock Bits
Reading the Signature Bytes
The algorithm for programming the Lock bits is as follows (refer to
page 184
The Lock bits can only be cleared by executing Chip Erase.
The algorithm for reading the Fuse and Lock bits is as follows (refer to
on page 184
Figure 20-6. Mapping Between BS1, BS2 and the Fuse and Lock Bits During Read
The algorithm for reading the Signature bytes is as follows (refer to
page 184
1. A: Load Command “0010 0000”.
2. C: Load Data Low Byte. Bit n = “0” programs the Lock bit. If LB mode 3 is programmed
3. Give WR a negative pulse and wait for RDY/BSY to go high.
1. A: Load Command “0000 0100”.
2. Set OE to “0”, BS2 to “0” and BS1 to “0”. The status of the Fuse Low bits can now be
3. Set OE to “0”, BS2 to “1” and BS1 to “1”. The status of the Fuse High bits can now be
4. Set OE to “0”, BS2 to “1”, and BS1 to “0”. The status of the Extended Fuse bits can now
5. Set OE to “0”, BS2 to “0” and BS1 to “1”. The status of the Lock bits can now be read at
6. Set OE to “1”.
1. A: Load Command “0000 1000”.
2. B: Load Address Low Byte (0x00 - 0x02).
3. Set OE to “0”, and BS1 to “0”. The selected Signature byte can now be read at DATA.
4. Set OE to “1”.
(LB1 and LB2 is programmed), it is not possible to program the Boot Lock bits by any
External Programming mode.
read at DATA (“0” means programmed).
read at DATA (“0” means programmed).
be read at DATA (“0” means programmed).
DATA (“0” means programmed).
for details on Command and Data loading):
for details on Command and Address loading):
for details on Command loading):
Extended Fuse Byte
Fuse Low Byte
Fuse High Byte
Lock Bits
BS2
BS2
0
1
0
1
BS1
0
1
“Programming the Flash” on
“Programming the Flash” on
“Programming the Flash”
DATA
189