ATTINY24-20MU Atmel, ATTINY24-20MU Datasheet - Page 27

IC MCU AVR 2K FLASH 20MHZ 20-QFN

ATTINY24-20MU

Manufacturer Part Number
ATTINY24-20MU
Description
IC MCU AVR 2K FLASH 20MHZ 20-QFN
Manufacturer
Atmel
Series
AVR® ATtinyr
Datasheets

Specifications of ATTINY24-20MU

Core Processor
AVR
Core Size
8-Bit
Speed
20MHz
Connectivity
USI
Peripherals
Brown-out Detect/Reset, POR, PWM, Temp Sensor, WDT
Number Of I /o
12
Program Memory Size
2KB (1K x 16)
Program Memory Type
FLASH
Eeprom Size
128 x 8
Ram Size
128 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
20-MLF®, QFN
Processor Series
ATTINY2x
Core
AVR8
Data Bus Width
8 bit
Data Ram Size
128 B
Interface Type
USI
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
12
Number Of Timers
2
Operating Supply Voltage
2.7 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
EWAVR, EWAVR-BL
Development Tools By Supplier
ATAVRDRAGON, ATSTK500, ATSTK600, ATAVRISP2, ATAVRONEKIT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit
For Use With
ATSTK600-DIP40 - STK600 SOCKET/ADAPTER 40-PDIP770-1007 - ISP 4PORT ATMEL AVR MCU SPI/JTAGATAVRISP2 - PROGRAMMER AVR IN SYSTEMATSTK505 - ADAPTER KIT FOR 14PIN AVR MCU
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATTINY24-20MU
Manufacturer:
AVNET
Quantity:
20 000
6.2.3
8006K–AVR–10/10
Internal 128 kHz Oscillator
ibrates the RC Oscillator. The accuracy of this calibration is shown as Factory calibration in
Table 20-2 on page
By changing the OSCCAL register from SW, see
page
The accuracy of this calibration is shown as User calibration in
When this Oscillator is used as the chip clock, the Watchdog Oscillator will still be used for the
Watchdog Timer and for the Reset Time-out. For more information on the pre-programmed cali-
bration value, see the section
Table 6-4.
Note:
When this oscillator is selected, start-up times are determined by the SUT Fuses as shown in
Table
Table 6-5.
Note:
The 128 kHz internal oscillator is a low power oscillator providing a clock of 128 kHz. The fre-
quency depends on supply voltage, temperature and batch variations. This clock may be
selected as the system clock by programming the CKSEL Fuses to “0100”.
When this clock source is selected, start-up times are determined by the SUT Fuses as shown in
Table
Table 6-6.
Note:
SUT1:0
SUT1:0
10
00
01
11
00
01
10
11
30, it is possible to get a higher calibration accuracy than by using the factory calibration.
(1)
6-5.
6-6.
1. The device is shipped with this option selected.
1. The device is shipped with this option selected.
2. If the RSTDISBL fuse is programmed, this start-up time will be increased to 14CK + 4 ms to
1. If the RSTDISBL fuse is programmed, this start-up time will be increased to 14CK + 4 ms to
ensure programming mode can be entered.
ensure programming mode can be entered.
Internal Calibrated RC Oscillator Operating Modes
Start-up Times for the Internal Calibrated RC Oscillator Clock Selection
Start-up Times for the 128 kHz Internal Oscillator
from Power-down
from Power-down
CKSEL3:0
176.
0010
Start-up Time
Start-up Time
6 CK
6 CK
6 CK
6 CK
6 CK
6 CK
(1)
“Calibration Byte” on page
Additional Delay from
Reset (V
Additional Delay
Reserved
“OSCCAL – Oscillator Calibration Register” on
Reserved
14CK + 64 ms
14CK + 64 ms
14CK + 4 ms
14CK + 4 ms
from Reset
14CK
14CK
CC
162.
(2)
(1)
= 5.0V)
Nominal Frequency
Table 20-2 on page
ATtiny24/44/84
8.0 MHz
Recommended Usage
BOD enabled
Fast rising power
Slowly rising power
BOD enabled
Fast rising power
Slowly rising power
Recommended
Usage
176.
27

Related parts for ATTINY24-20MU