DS2151QNB+ Maxim Integrated, DS2151QNB+ Datasheet - Page 17

no-image

DS2151QNB+

Manufacturer Part Number
DS2151QNB+
Description
Network Controller & Processor ICs
Manufacturer
Maxim Integrated
Datasheet

Specifications of DS2151QNB+

Product
Framer
Number Of Transceivers
1
Data Rate
2.048 Mbps
Supply Current (max)
65 mA
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
PLCC-44
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
5 V
Supply Voltage - Max
5.25 V
Supply Voltage - Min
4.75 V
Part # Aliases
90-2151Q+NB0
CCR3: COMMON CONTROL REGISTER 3 (Address = 30 Hex)
ESMDM
(MSB)
SYMBOL
ESMDM
LIRST
RSMS
P16F
PDE
TLD
TLU
ESR
ESR
POSITION
CCR3.7
CCR3.6
CCR3.5
CCR3.4
CCR3.3
CCR3.2
CCR3.1
CCR3.0
P16F
NAME AND DESCRIPTION
Elastic Store Minimum Delay Mode. See Section
details.
0=elastic stores operate at full two-frame depth
1=elastic stores operate at 32-bit depth
Elastic Store Reset. Setting this bit from a 0 to a 1 will force
the elastic stores to a known depth. Should be toggled after
SYSCLK has been applied and is stable. Must be cleared and
set again for a subsequent reset.
Function of Pin 16.
0 = Receive Loss of Sync (RLOS).
1 = Loss of Transmit Clock (LOTC).
RSYNC Multiframe Skip Control. Useful in framing format
conversions from D4 to ESF.
0 = RSYNC will output a pulse at every multiframe
1 = RSYNC will output a pulse at every other multiframe note:
for this bit to have any affect, the RSYNC must be set to output
multiframe pulses (RCR2.4 = 1 and RCR2.3 = 0) and the
receive elastic store must be bypassed. (CCR1.2 = 0).
Pulse Density Enforcer Enable.
0 = disable transmit pulse density enforcer
1 = enable transmit pulse density enforcer
Transmit Loop Down Code (001).
0 = transmit data normally
1 = replace normal transmitted data with Loop Down code
Transmit Loop Up Code (00001).
0 = transmit data normally
1 = replace normal transmitted data with Loop Up code
Line Interface Reset. Setting this bit from a 0 to a one will
initiate an internal reset that affects the slicer, AGC, clock
recovery state machine and jitter attenuator. Normally this bit is
only toggled on power-up. Must be cleared and set again for a
subsequent reset.
RSMS
17 of 60
PDE
TLD
TLU
LIRST
(LSB)
11
for

Related parts for DS2151QNB+