6.3.3.3
4679D–4BMCU–05/05
Timer 3 Modulator/Demodulator Modes
Timer 3 – Mode 3:
The counter is driven by an internal or external (T3I) clock source. The output toggle signal of
Timer 2 resets the counter. The counter value before the reset is saved in the capture register. If
single-action mode is activated for one or both compare registers, the trigger signal restarts the
single actions. This mode can be used for frequency measurements or as event counter with
time gate (see section “Combination Mode 10”).
Figure 6-30. Event Counter with Time Gate
Timer 3 - Mode 4: Timer/Counter
The timer runs as timer/counter in mode 1, but its output T3O is used as output for the Timer 2
output signal.
Timer 3 – Mode 5:
The Timer 3 runs as timer/counter in mode 2, but its output T3O is used as output for the Timer
2 output signal.
Timer 3 – Mode 6:
The Timer 3 counter is driven by an internal or external clock source. Its compare- and compare
mode registers must be programmed to generate the carrier frequency via the output toggle
flip-flop. The output toggle flip-flop of Timer 2 is used to enable or disable the Timer 3 output.
Timer 2 can be driven by the toggle output signal of Timer 3 or any other clock source (see sec-
tion “Combination Mode 11”).
Timer 3 – Mode 7:
The Timer 3 counter is driven by an internal or external clock source. Its compare- and compare
mode registers must be programmed to generate the carrier frequency via the output toggle
flip-flop. The output (SO) of the SSI is used to enable or disable the Timer 3 output. The SSI
should be supplied with the toggle signal of Timer 2 (see section “Combination Mode 12”).
Counter 3
Register
T3CP-
TOG2
T3R
T3I
0 0 1 2 3 4 5 6 7 8 9 10
Timer/Counter, Internal Trigger Restart and Internal Capture
(with TOG2)
Timer/Counter, External Trigger Restart and External Capture
(with T3I Input)
Carrier Frequency Burst Modulation Controlled by Timer 2 Output
Toggle Flip-Flop (M2)
Carrier Frequency Burst Modulation Controlled by SSI Internal
Output (SO)
Capture value = 0
11
0 1
2
Capture value = 11
3
4
ATAM894
0 1
Capture
value = 4
2
51