EPM2210F100A ALTERA [Altera Corporation], EPM2210F100A Datasheet - Page 60

no-image

EPM2210F100A

Manufacturer Part Number
EPM2210F100A
Description
MAX II Device Family
Manufacturer
ALTERA [Altera Corporation]
Datasheet
5–2
Recommended Operating Conditions
Table 5–2. MAX II Device Recommended Operating Conditions
MAX II Device Handbook
V
V
V
V
T
Notes to
(1) MAX II device in-system programming and/or user flash memory (UFM) programming via JTAG or logic array is not guaranteed outside the
(2) Minimum DC input is –0.5 V. During transitions, the inputs may undershoot to –2.0 V for input currents less than 100 mA and periods shorter
(3) During transitions, the inputs may overshoot to the voltages shown in the following table based upon input duty cycle. The DC case is equivalent
(4) All pins, including clock, I/O, and JTAG pins, may be driven before V
(5) MAX IIZ devices are only available in the commercial temperature range.
(6) For the extended temperature range of 100 to 125º C, MAX II UFM programming (erase/write) is only supported via the JTAG interface. UFM
J
CCINT
CCIO
I
O
Symbol
recommended operating conditions (for example, if brown-out occurs in the system during a potential write/program sequence to the UFM,
users are recommended to read back UFM contents and verify against the intended write data).
than 20 ns.
to 100% duty cycle. For more information about 5.0-V tolerance, refer to the
II Device Handbook.
V
4.0 V
4.1
4.2
4.3
4.4
4.5
programming via the logic array interface is not guaranteed in this range.
(1)
IN
(1)
Table
Max. Duty Cycle
100% (DC)
17%
90%
50%
30%
10%
3.3-V supply voltage for internal logic and
ISP
2.5-V supply voltage for internal logic and
ISP
1.8-V supply voltage for internal logic and
ISP
Supply voltage for I/O buffers, 3.3-V
operation
Supply voltage for I/O buffers, 2.5-V
operation
Supply voltage for I/O buffers, 1.8-V
operation
Supply voltage for I/O buffers, 1.5-V
operation
Input voltage
Output voltage
Operating junction temperature
5–2:
Table 5–2
Parameter
shows the MAX II device family recommended operating conditions.
MAX II devices
MAX II devices
MAX IIG and MAX IIZ
devices
Commercial range
Industrial range
Extended range
CCINT
and V
(2), (3),
Conditions
Using MAX II Devices in Multi-Voltage Systems
CCIO
are powered.
(4)
(6)
(5)
Chapter 5: DC and Switching Characteristics
Minimum
© Novermber 2008 Altera Corporation
2.375
2.375
1.425
3.00
1.71
3.00
1.71
–0.5
–40
–40
0
0
Maximum
2.625
2.625
1.575
Operating Conditions
3.60
1.89
3.60
1.89
V
100
125
4.0
chapter in the MAX
85
CCIO
Unit
°C
°C
°C
V
V
V
V
V
V
V
V
V

Related parts for EPM2210F100A