S71PL064JB0BFW0B0 Spansion Inc., S71PL064JB0BFW0B0 Datasheet - Page 74

no-image

S71PL064JB0BFW0B0

Manufacturer Part Number
S71PL064JB0BFW0B0
Description
Manufacturer
Spansion Inc.
Datasheet

Specifications of S71PL064JB0BFW0B0

Operating Supply Voltage (max)
3.1V
Operating Temperature (max)
85C
Mounting
Surface Mount
Lead Free Status / RoHS Status
Compliant
Command (Notes)
Reset
SecSi Sector Entry
SecSi Sector Exit
SecSi Protection Bit
Program (Notes 5, 6)
SecSi Protection Bit
Status
Password Program
(Notes 5, 7, 8)
Password Verify (Notes
6, 8, 9)
Password Unlock (Notes
7, 10, 11)
PPB Program (Notes 5,
6, 12)
PPB Status
All PPB Erase (Notes 5,
6, 13, 14)
PPB Lock Bit Set
PPB Lock Bit Status
(Note 15)
DYB Write (Note 7)
DYB Erase (Note 7)
DYB Status (Note 6)
PPMLB Program (Notes
5, 6, 12)
PPMLB Status (Note 5)
SPMLB Program (Notes
5, 6, 12)
SPMLB Status (Note 5)
75
Legend:
BA = Address of bank switching to autoselect mode, bypass
mode, or erase operation. Determined by PL127J: Amax:A20,
PL064J: Amax:A19, PL032J: Amax:A18.
PA = Program Address (Amax:A0). Addresses latch on falling
edge of WE# or CE# pulse, whichever happens later.
PD = Program Data (DQ15:DQ0) written to location PA. Data
latches on rising edge of WE# or CE# pulse, whichever happens
first.
Notes:
1. See Table
2. All values are in hexadecimal.
3. Shaded cells in table denote read cycles. All other cycles are
4. During unlock and command cycles, when lower address bits
5. No unlock or command cycles required when bank is reading
6. The Reset command is required to return to reading array
7. Fourth cycle of autoselect command sequence is a read
8. The data is C0h for factory and customer locked and 80h for
write operations.
are 555 or 2AAh as shown in table, address bits higher than
A11 (except where BA is required) and data bits higher than
DQ7 are don’t cares.
array data.
(or to erase-suspend-read mode if previously in Erase
Suspend) when bank is in autoselect mode, or if DQ5 goes
high (while bank is providing status information).
cycle. System must provide bank address to obtain
manufacturer ID or device ID information. See Autoselect
Command Sequence section for more information.
factory locked.
1
for description of bus operations.
1
3
4
6
5
4
4
7
6
4
6
3
4
4
4
4
6
5
6
5
Addr
XXX
555
555
555
555
555
555
555
555
555
555
555
555
555
555
555
555
555
555
555
Data
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
F0
Table 18. Sector Protection Command Definitions
Addr
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
Data Addr Data
S29PL127J/S29PL064J/S29PL032J for MCP
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
555
555
555
555
555
555
555
555
555
555
555
555
555
555
555
555
555
555
555
88
90
60
60
38
C8
28
60
90
60
78
58
48
48
58
60
60
60
60
P r e l i m i n a r y
PWA[0-3] PWD[0-3]
XX[0-3]
PWA[0]
(SA)WP
(SA)WP
Addr
OW
OW
WP
XX
SA
SA
SA
SA
SL
SL
PL
PL
Bus Cycles (Notes 1-4)
RA = Read Address (Amax:A0).
RD = Read Data (DQ15:DQ0) from location RA.
SA = Sector Address (Amax:A12) for verifying (in autoselect
mode) or erasing.
WD = Write Data. See “Configuration Register” definition for
specific write data. Data latched on rising edge of WE#.
X = Don’t care
9. The data is 00h for an unprotected sector group and 01h for
10. Device ID must be read across cycles 4, 5, and 6. PL127J
11. System may read and program in non-erasing sectors, or
12. Program/Erase Resume command is valid only during Erase
13. Command is valid when device is ready to read array data or
14. WP#/ACC must be at V
15. Unlock Bypass Entry command is required prior to any
a protected sector group.
(X0Eh = 2220h, X0Fh = 2200h),PL064J (X0Eh = 2202h,
X0Fh = 2201h), PL032J (X0Eh = 220Ah, X0Fh = 2201h).
enter autoselect mode, when in Program/Erase Suspend
mode. Program/Erase Suspend command is valid only
during a sector erase operation, and requires bank address.
Suspend mode, and requires bank address.
when device is in autoselect mode.
command.
Unlock Bypass operation. Unlock Bypass Reset command is
required to return to the reading array.
PD[0-3]
PWD[0]
RD(0)
RD(1)
RD(0)
Data
X1
X0
00
68
48
68
60
68
48
68
48
PWA[1] PWD[1] PWA[2] PWD[2] PWA[3] PWD[3]
(SA)WP
Addr
(SA)
OW
OW
SL
SL
PL
PL
RD(0)
RD(0)
RD(0)
Data
48
48
40
48
48
ID
during the entire operation of
S29PL127_064_032J_00_A1 May 21, 2004
(SA)WP
(SA)WP
Addr
OW
PL
SL
RD(0)
RD(0)
RD(0)
RD(0)
RD(0)
Data
Addr
Data

Related parts for S71PL064JB0BFW0B0