MAX1441GUP/V+ Maxim Integrated Products, MAX1441GUP/V+ Datasheet - Page 13

Touch Screen Converters & Controllers PROXIMITY SENSR el Proximity and Tou

MAX1441GUP/V+

Manufacturer Part Number
MAX1441GUP/V+
Description
Touch Screen Converters & Controllers PROXIMITY SENSR el Proximity and Tou
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX1441GUP/V+

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 4. Special-Purpose Registers’ Reset Values
Table 5. Special-Purpose Register Bit Description
AP (00h, 08h)
Initialization
Read/Write Access
AP[1:0]
AP[7:2]
APC (01h, 08h)
Initialization
Read/Write Access
APC[1:0]–MOD[1:0]
APC[5:2]
APC.6–IDS
APC.7–CLR
REGISTER
WDCN
CKCN
APC
PSF
IMR
REGISTER
AP
SC
IIR
A0
A1
A2
A3
IC
MSB
0000
0000
0000
0000
Automotive, Two-Channel Proximity and
Accumulator Pointer (8-Bit Register)
This register is cleared to 00h on all forms of reset.
Unrestricted read/write.
Active Accumulator Select Bits [1:0]. The setting of these bits activates one of the four accumulators
in the accumulator module (A) to function as the active accumulator for arithmetic and logical opera-
tions. The setting of these bits can be automatically incremented/decremented in a modulo fashion
according to the setting to the APC register.
Reserved. Read returns 0.
Accumulator Pointer Control (8-Bit Register)
This register is cleared to 00h on all forms of reset.
Unrestricted read/write.
Modulo Bits [1:0]. The accumulator pointer autoincrement/decrement function is activated when these
bits are set to a value other than 00b. The modulo is selected accordingly when active pointer autoincre-
ment/decrement is active.
Reserved. Read returns 0.
Increment/Decrement Select. When this bit is cleared to 0, the content of AP increments after an arith-
metic or logical operation. When this bit is set to 1, the content of AP is decremented after arithmetic or
logical operation.
AP Clear. When this bit is set to 1, the content of AP is cleared to 0. This bit automatically resets to 0
after clearing the AP register. Note if the MOVE APC, Acc instruction (980Ah) causes the CLR bit to set,
the clear operation overrides other functions (i.e., the AP autoincrement/decrement does not happen).
0000
0000
0000
0000
MOD[1:0]
0000
0000
1000
0000
0000
1000
0000
1110
ss11
0000
0000
0000
0000
00
01
10
11
0000
0000
0000
0000
0000
00s0
0000
0000
0000
0000
0000
0000
LSB
0ss0
Default, no AP autoincrement/decrement
Modulo 2
Modulo 4
Reserved (modulo 4 if set)
DESCRIPTION
REGISTER
GRXL
GRH
DPC
GRL
GRS
LC0
LC1
DP0
PFX
GR
SP
IP
IV
MSB
0000
1000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Touch Sensor
MODULO
0000
0000
0000
0111
0000
0000
0000
0000
0000
0000
0000
0000
0000
0010
1111
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
1111
1101
0000
0000
0100
0000
0000
0000
0000
0000
0000
LSB
13

Related parts for MAX1441GUP/V+