DC-2R5E224U-E Elna America, DC-2R5E224U-E Datasheet - Page 22

CAP DOUBLE LAYER .22F 2.5V COIN

DC-2R5E224U-E

Manufacturer Part Number
DC-2R5E224U-E
Description
CAP DOUBLE LAYER .22F 2.5V COIN
Manufacturer
Elna America
Series
DCr
Datasheets

Specifications of DC-2R5E224U-E

Capacitance
220mF
Voltage - Rated
2.5V
Tolerance
-20%, +80%
Esr (equivalent Series Resistance)
100.00 Ohm
Lifetime @ Temp.
1000 Hrs @ 70°C
Mounting Type
Surface Mount
Package / Case
Surface Mount - Coin Style
Lead Spacing
0.079" (2.00mm)
Height
0.295" (7.50mm)
Size / Dimension
0.268" Dia (6.80mm)
Operating Temperature
-25°C ~ 70°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
604-1006
TECHNICAL NOTE
• During cleaning, control the cleaning solution
6. Fixing adhesives and coating materials.
• Do not use halogenated fixatives and coatings.
• Before using a fixative or coating, remove flux
• Dry the cleaning solution before using the adhesive
• Do not cover up all the sealing sections (terminal
• Heat curing conditions of fixative and coating.
1. Do not directly touch the terminals of solid con-
ductive polymer aluminum electrolytic capacitors.
Failure to do so can cause electric shock or burns.
Before use, allow capacitors to discharge through a
1kΩ resistor (with a sufficient margin to the heat
generation capacity) as needed.
2. Do not short-circuit between the terminals of
the solid conductive polymer aluminum electrolytic
capacitors with electric conductor. Do not subject
capacitors to conductive solutions such as acid
and alkaline water solutions.
3. Periodic inspection should be performed on the
capacitors for the industrial equipment application.
Check the following checkpoints.
• Visual inspection to check for significant defects.
• Electrical performance: leakage current, rated
4. Be careful of the following cases of emergency.
• In case of a short during use of capacitors in sets,
• In case of a short, producing gas, it may take a few
• If the gas gets in your eyes, rinse them immediately.
• Do not lick the electrolyte of capacitors. When the
5. Storage Conditions.
• Do not store at high temperature and high humidity.
CAT.No.2008/2009E ( 2008.10.1 )
against contamination.
residues and contaminants from between the PCB
and the sealing section of capacitors.
or coating.
side) of capacitors with the adhesive or coating.
capacitance, tangent of loss angle, ESR, and items
specified in the catalog or delivery specification.
producing gas, turn off the main power of the set or
unplug the power cord from the outlet.
seconds to a few minutes depending on the
conditions. Therefore, ensure that the protective circuit
of the power supply works during this time.
Gargle if the gas is inhaled.
electrolyte gets on your skin, wash it off with soap
immediately.
Store at a temperature of 5 to 35°C and a relative
humidity of less than 75%, keeping free from direct
sunlight.
Other Cautions
ALUMINUM ELECTROLYTIC CAPACITORS
WITH CONDUCTIVE POLYMER SOLID ELECTROLYTE
• During delivery, capacitors are stored in airtight
• Solid conductive polymer aluminum electrolytic
Please check that recommended voltage treatment
conditions are provided for each series.
• Do not store capacitors in an environment directly
• Do not store capacitors in an environment filled with
• Do not store capacitors in a place exposed to ozone,
6. Please take the following actions when
disposing of solid conductive polymer aluminum
electrolytic capacitors.
• Entrust to specialists of industrial waste treatment for
7. Others
• Before using capacitors, check the details of this
Technical Report of Japan Electronics and Information
Technology Industries Association
EIAJ RCR-2367B
Guideline of notabilia for fixed aluminum electrolytic
capacitors for use in electronic equipment
moistureproof bags to ensure satisfactory soldering.
Once the bag is opened right before mounting, it is
better to use up the capacitors. If some are unavoid-
ably left over, return them to the moistureproof bag,
and seal the opening hermetically.
capacitors may have increased leakage current
when unused or stored for a long time after mounted
on equipment. This phenomenon often occurs at
high ambient temperatures; however, leakage
current will decrease through voltage treatment. If
leakage current still increases after a lapse of more
than one year at ambient temperature (shorter time
at high temperatures), treat with voltage as needed.
In design of equipment, consider the effect of
increase in initial current, and install protective
circuits as needed.
exposed to water, saltwater spray, oil spill or
condensation.
toxic gas such as hydrogen sulfide, sulfurous acid,
nitrous acid, chlorine, ammonia, etc.
ultraviolet rays, or radiation.
incineration.
delivery specification and catalog as well as the
following.
NOTE
Design, Specifications are subject to change without notice.