24H1601-2R POWER ONE, 24H1601-2R Datasheet
24H1601-2R
Specifications of 24H1601-2R
Related parts for 24H1601-2R
24H1601-2R Summary of contents
Page 1
Description The H series of DC-DC converters represents a broad and flexible range of cassette power supplies for use in advanced electronic systems. Features include high efficiency, reliability, and reasonable output voltage noise. The converter inputs are ...
Page 2
... REV. MAR 27, 2006 50 Watt DC-DC Cassette Converters Input Voltage Range and Efficiency η nom i min max min 2 [ VDC [%] VDC - 12H1001- 12H1301-2R 79 24H1301-2R - 12H1501-2R 80 24H1501-2R - 12H1601-2R 81 24H1601- 12H1901-2R 83 24H1901-2R - 12H2320-2 79 24H2320-2 - 12H2540-2 80 24H2540-2 0.7 12H3020-2 77 24H3020-2 0.6 12H3040-2 77 24H3040 VDC ............. 12 5.1 V ............... ............... ............... ............... ............... ............. ............. 40 ...
Page 3
Functional Description The input voltage is fed via an input filter to the input capacitor. This capacitor sources a single-transistor forward converter. Each output is powered by a separate secondary winding of the main transformer. The resultant voltages are rectified ...
Page 4
Electrical Input Data General conditions: – °C, unless T is specified – Connector pins 2 and 23 interconnected, R input not connected. Table 2: Input data Input Characteristics Conditions V Operating input voltage I = ...
Page 5
Electrical Output Data General conditions – °C, unless T is specified – Connector pins 2 and 23 interconnected, R input not connected. Table 4a: Output data Output Characteristics Conditions V Output voltage ...
Page 6
Output Protection Each output is protected against overvoltages which could occur due to a failure of the internal control circuit. Voltage suppressor diodes (which under worst case condition may become a short circuit) provide the required protection. The suppressor diodes ...
Page 7
Thermal Considerations If a converter is located in free, quasi-stationary air (convection cooling) at the indicated maximum ambient temperature T (see table: Temperature specifications) A max and is operated at its nominal input voltage and output power, the temperature measured ...
Page 8
Auxiliary Functions i Inhibit for Remote On and Off Note: With open i input: Output is disabled ( V The outputs of the module may be enabled or disabled by means of a logic signal (TTL, CMOS, etc.) applied between ...
Page 9
Table 7a: R for V < V (conditions nom nom o nom V [V] R [kΩ 0.5 0.432 2.0 1.0 0.976 3.0 1.5 1.65 4.0 ...
Page 10
Electromagnetic Compatibility (EMC) A suppressor diode together with an input filter form an effective protection against input transient voltages which typically occur in most installations, but especially in Electromagnetic Immunity Table 8: Immunity type tests 1 Phenomenon Standard Level Electrostatic ...
Page 11
Mechanical Data Dimensions in mm. Tolerances ±0.3 mm unless otherwise indicated. 100 (11.6) 94.5 17.25 12.17 7. (LED green) Inhibit i (LED red) Potentiometer (option Fig. 12 DC-DC converter in case H02, weight 770 g ...
Page 12
Immunity to Environmental Conditions Table 10: Mechanical stress Test method Standard Ca Damp heat IEC/DIN IEC 60068-2-3 steady state MIL-STD-810D section 507.2 Ea Shock IEC/EN/DIN EN 60068-2-27 (half-sinusoidal) MIL-STD-810D section 516.3 Eb Bump IEC/EN/DIN EN 60068-2-29 (half-sinusoidal) MIL-STD-810D section 516.3 ...
Page 13
Installation Instructions The H series DC-DC converters are components, intended exclusively for inclusion within other equipment by an industrial assembly operation or by professional installers. Installation must strictly follow the national safety regulations in compliance with the enclosure, mounting, creepage, ...
Page 14
Safety of operator accessible output circuit If the output circuit of a DC-DC converter is operator accessible, it shall be a SELV circuit according to the IEC/ EN 60950 related safety standards. Since the H series DC-DC converters provide double ...
Page 15
Description of Options Table 16: Survey of options Option Function of Option -7 Extended operational ambient temperature range 1 D Input and/or output undervoltage monitoring circuitry Input and output undervoltage monitoring circuitry 1 Option D excludes option ...
Page 16
Threshold tolerances and hysteresis monitored, the internal input voltage after the input i filter is measured. Consequently this voltage differs from the voltage at the connector pins by the voltage drop Δ V across the input filter. ...
Page 17
V ACFAIL signal (VME) Available for units with This option defines an undervoltage monitoring circuit for the input or the input and main output voltage equivalent to option D, and generates the ACFAIL signal (V ...
Page 18
Threshold tolerances and hysteresis monitored, the internal input voltage is measured i after the input filter. Consequently this voltage differs from the voltage at the connector pins by the voltage drop Δ V across input filter and ...
Page 19
Accessories A variety of electrical and mechanical accessories are available including: – Front panels for 19" rack mounting, Schroff and Intermas systems. – Mating H11 connectors with screw, solder, fast-on or press-fit terminals. – Connector retention facilities. – Code key ...