H5S-WB2 Omron, H5S-WB2 Datasheet - Page 8

TIMER DIGITAL WEEKLY 100-240VAC

H5S-WB2

Manufacturer Part Number
H5S-WB2
Description
TIMER DIGITAL WEEKLY 100-240VAC
Manufacturer
Omron
Series
H5Sr
Datasheets

Specifications of H5S-WB2

Supply Voltage
100 V to 240 V
Current Rating (max)
100 mA
Product
Digital Timer
Termination Style
Screw
No. Of Digits / Alpha
2
Meter Function
Counter
Supply Voltage Max
240VAC
Supply Voltage Min
100VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
Z2504
2. First Circuit Operation Setting
3. Fist Circuit Day-of-the-week Setting
By pressing the Mode Key, place the H5L into DAY SET mode.
The display will be as shown on the left.
Press the Plus Key to operate the first circuit on a particular day of the week and press the Minus Key to stop it.
The reverse video (i.e., white characters on a black background) of the day-of-the-week indicators means that
the first circuit is operated on that day. The day on which circuit operation is stopped is indicated by bold
indicators. Initially, the circuit is set to operates on all the days of the week and the SUN indicator blinks.
In this example, since circuit operation is to be stopped on Sunday, select SUN and press the Minus Key, then
store the setting in memory by pressing the Write Key.
To program the operation of the first circuit, "hour", "minute", and "output" must be specified.
Press the Mode Key to place the H5L into PROG 1 mode. The display will be as shown on the left.
The output status indicator starts blinking. Set the output to the OFF state using the Minus Key and
store it in memory by pressing the Write Key.
Since the first circuit is to be turned ON at 7:40, set the "hour" to 7 by pressing the Plus or Minus
Key and then store it in memory by using the Write Key.
The display returns to the initial state as shown on the left and waits for the next program command to be input.
The MON indicator will start blinking. Press the Write Key, until the SAT indicator blinks.
Since the first circuit is not to be operated on Saturday, press the Minus Key followed by the Write Key.
The display returns to the initial state and waits for the next program command to be input. Now let us turn
to the setting of the "day of the week".
The "minute" will start blinking. Set it to 40 by using the Plus or Minus Key and store it in memory
by pressing the Write Key.
Now, the output status indicator will blink. Set the output to the ON state with the Plus Key
followed by the Write Key.
(If the Plus Key is pressed twice at this time, the display will give an invalid indication, and if the
Write Key is pressed, this program will be deleted.)
Since the first circuit should be turned OFF at 19:30, set the hour to 19 and the minute to 30 by
using the Plus or Minus Key and then the Write Key.
The SUN indicator will start blinking again. This completes the setting of all the days of the week for the
first circuit.
H5L
8

Related parts for H5S-WB2