H5S-WB2 Omron, H5S-WB2 Datasheet - Page 6

TIMER DIGITAL WEEKLY 100-240VAC

H5S-WB2

Manufacturer Part Number
H5S-WB2
Description
TIMER DIGITAL WEEKLY 100-240VAC
Manufacturer
Omron
Series
H5Sr
Datasheets

Specifications of H5S-WB2

Supply Voltage
100 V to 240 V
Current Rating (max)
100 mA
Product
Digital Timer
Termination Style
Screw
No. Of Digits / Alpha
2
Meter Function
Counter
Supply Voltage Max
240VAC
Supply Voltage Min
100VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
Z2504
Deleting Programming
1. Deleting from Normal Operation Programs (ON Time/OFF
■ LCD Display
LCD Display (Display Example in Each Mode)
Since the H5L employs interactive programming, the program mode and setting data are displayed on the LCD.
Note: Meaning of output status indications
■ Programming Example
Be sure to create a timing chart before programming.
Operating Timing Chart
First Circuit
Second Circuit
Time)
Call up the output display for the program to be deleted by
pressing the Write Key. The minus sign (–) for the output point will
flash.
Next, change the display to disable the output using the Plus and
Minus Keys. For NC contacts, press the Plus Key and for NO
contacts, press the Minus Key. The connecting bar above the
contacts will disappear and the display will flash to indicate that
the output has been displayed. If the Write Key is pressed at this
time, the step will be deleted.
:Output ON,
Display
; Output OFF,
RUN
Current time
setting
First operation
time setting
First weekday
setting
Mode
: Invalid (if an invalid instruction is written to a step, that step will be cleared.)
Current day of week:
Monday
Current time:10:11
First circuit: OFF
Second circuit: ON
Current day of week:
Tuesday
Current time: 9:31
The first circuit turns on at
8:15
The first circuit turns OFF
on Sunday and Saturday
(operation by the set
program stops). It turns ON
Monday to Friday (operation
by the set program is
executed).
Display data
2. Deleting from Cyclic Programs
Four steps will be simultaneously deleted from the cyclic program
if the program is called up and then the Cycle and Write Keys are
pressed in order. The start time display will remain, but the
program will be deleted.
Display
Second
operation time
setting
Second
Weekday
setting
Cycle Program
setting
Memory over
Mode
The second circuit turns ON
Sunday to Thursday
(operation by the set
program is executed). It
turns OFF on Friday and
Saturday (operation by the
set program stops).
The second circuit turns ON
Sunday to Thursday
(operation by the set
program is executed). It
turns OFF on Friday and
Saturday (operation by the
set program stops).
The first circuit starts cycle
operation at 1:10 (for
details, refer to Cycle
Program).
Indicates that all 24
program steps have been
written (on writing the 24th
step, the data set for the first
step is displayed on the
LCD).
Display data
H5L
6

Related parts for H5S-WB2