H5S-B Omron, H5S-B Datasheet

TIMER DIGITAL WEEKLY 100-240VAC

H5S-B

Manufacturer Part Number
H5S-B
Description
TIMER DIGITAL WEEKLY 100-240VAC
Manufacturer
Omron
Series
H5Sr
Datasheet

Specifications of H5S-B

Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
H5SB
Z1143
1
Timer Provides Prompted Programming,
Flexibility in Programs Within the Week
Ordering Information
Timing function
Contact type
Terminal form
Mounting
Part number
Supply voltage
Description
Hard plastic cover
Track mounting adapter for H5S-FB
Mounting track
Time setting range
Program capacity
Cycle length
Display time division
Operation
Weekly Timer
TIMERS
TIME RANGES
ACCESSORIES
AM/PM display
24 program steps
A different program possible each day
Over midnight settings possible
Two independent 15 A control circuits
Automatic or manual operation following
Field-adjustable ON/OFF, cycle and
Easy-to-use prompted programming
Wide supply voltage range
Battery backup for memory protection
Protective cover and other accessories
with manual override
power failure
pulse output
may be ordered separately
ON/OFF and cycle operations up to one week
Two SPST-NO time limit contacts with manual override switches
Screw terminals
Panel mounting
H5S-B
100 to 240 VAC, 50/60 Hz
00:00 a.m. to 11:59 p.m.
24 steps: ON = 1 step, OFF = 1 step, CYCLE = 4 steps, PULSE = 1 step
From 1 minute up to a full week
1 minute
Weekly operation (multiple-day operation possible)
Cycle operation
Pulse-out operation (pulse width can be set in units of 1 second from 1 to 59 seconds and in units
of 1 minute from 1 to 60 minutes)
Day override operation (operation for one day can be also executed on any other day)
Forced ON/OFF operation
Manual or automatic operation selectable on recovery from power failure
50 cm (1.64 ft) length
1 m (3.28 ft) length
End plate
Surface or track mounting
H5S-FB
Part number
Y92A-72C
Y92F-90
PFP-50N
PFP-100N
PFP-M
H5S

Related parts for H5S-B

H5S-B Summary of contents

Page 1

... Contact type Two SPST-NO time limit contacts with manual override switches Terminal form Screw terminals Mounting Panel mounting Part number H5S-B Supply voltage 100 to 240 VAC, 50/60 Hz TIME RANGES Time setting range 00:00 a.m. to 11:59 p.m. Program capacity 24 steps step, OFF = 1 step, CYCLE = 4 steps, PULSE = 1 step ...

Page 2

... Mechanical durability Malfunction durability Variation due to voltage change Variation due to temperature change Insulation resistance Dielectric strength Service life Electrical 2 H5S-B 100 to 240 V, 50/60 Hz – 110% of rated voltage (85 to 264 VAC), 50/ – ON and OFF programming No-voltage, 0.2 sec minimum SPST- circuits 1 sec to 59 seconds or 1 min to 60 min ...

Page 3

... H5S Dimensions Unit: mm (inch) TIMERS H5S-B Panel-Mounting Type H5S-FB Surface-Mounting Type 126.7 (4.99) PROTECTIVE COVER Y92A-72C 75 (2.95) 75 12.5 (0.49) (2.95) overall depth 72 49 (2.83) (1.93) 72 (2.83) 72 58.5 (2.30) 49 (1.93 (2.83) (1.46) 67.6 (2.66) 17.7 (0.69 (2.83) (2.83) 58.5 (2.30) 68 (2.68) The hard plastic protective cover prevents accidental resetting ...

Page 4

... PFP-100N/PFP-50N DIN Rail Connections H5S-B PANEL MOUNTING TYPE (Rear view) Power source for load 2 When separate power sources are used for load and H5S. H5S-B PANEL MOUNTING TYPE (Rear view) *Power restoration input Output 100 to 240 VAC Power Source 4 The H5S-FB timer can be mounted on DIN rail track using the Y92F-90 adapter ...

Page 5

... Operation NOMENCLATURE Front Panel with Cover Open Display AC common Power source for load 2 AC hot When separate power sources are used for load and H5S When load and H5S share the same power source AC common Power source AC hot Key Operations No. ...

Page 6

... Note that the signal must be a low to high transition (open to closed switching). Executes a day's operation on another day. The specified new operation is performed only for one week. This could be used for holidays. H5S In this example, circuit 1 performs an ordinary timer operation, while circuit ...

Page 7

... The time and day can also be adjusted or changed while the timer is operating. In the following example, the current set time, 10:30 a.m., Wednesday, is changed to 4:00 a.m., Monday. Ordinary Timer Operation In this example, circuit 1 is set to operate at 8:30 a.m. and stop at 5:15 p.m., from Monday through Friday. Set mode switch to P1. H5S 7 ...

Page 8

... Cycle Operation Circuit 1 is set to turn ON for 2 minutes and OFF for 1 minute repeatedly, from 8:30 a.m. to 5:15 p.m. on Monday. Set mode selector to P1. Pulse Output Operation Circuit 2 is turned ON for 30 seconds at 8:25 a.m., Monday through Friday. Set mode selector to P2. 8 H5S ...

Page 9

... In the following example, the times set for today are checked. Set mode selector switch to RUN also possible to check the timing operations in the sequence they are to be executed. The operations to be performed Thursday are checked. Mode selector switch is in RUN. H5S 9 ...

Page 10

... If both settings 1 and 2 are for an ON/OFF or pulse operation, the output is continuously produced without being interrupted. For example, if setting 1 is for cyclic operation, and 2 is set for an ON/OFF operation, the cyclic operation is performed during period and the ON/OFF operation is performed from H5S ...

Page 11

... RUN position and confirm that the automatic operation indicator lights. The set data may be erased if the OUT switch is moved between the TIMER and PULSE positions after the data has been set. Mounting PANEL MOUNTING H5S-B 49 (1.93) Panel cutout (2.68) SURFACE MOUNTING H5S-FB 126 ...

Page 12

... H5S TRACK MOUNTING H5S-FB Use Y92F-90 Track Mounting Base 79.8 (3.14) NOTE: ALL DIMENSIONS ARE IN MILLIMETERS. To convert millimeters into inches divide by 25.4. Omron Europe B.V. EMA-ISD, tel:+31 23 5681390, fax:+31 23 5681397, http://www.eu.omron.com/ema Cat. No. GC TI8 11/97 12 Specifications subject to change without notice. ...