H5S-WB2 Omron, H5S-WB2 Datasheet - Page 2

TIMER DIGITAL WEEKLY 100-240VAC

H5S-WB2

Manufacturer Part Number
H5S-WB2
Description
TIMER DIGITAL WEEKLY 100-240VAC
Manufacturer
Omron
Series
H5Sr
Datasheets

Specifications of H5S-WB2

Supply Voltage
100 V to 240 V
Current Rating (max)
100 mA
Product
Digital Timer
Termination Style
Screw
No. Of Digits / Alpha
2
Meter Function
Counter
Supply Voltage Max
240VAC
Supply Voltage Min
100VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
Z2504
■ Characteristics
Note: The overall error, which includes repeat accuracy, setting error, and variations due to changes in voltage and temperature, is ±0.01% or
Engineering Data
Ambient Operating Temperature and Carry Current
Note that the upper limit of the ambient operating temperature
lowers when a large carry current is being applies as shown below.
Accuracy of operating time
Setting error
Influence of voltage
Influence of temperature
Time accuracy
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Approved standards
Weight
±0.05 s max. The accuracy of ±0.01% also indicates the error in the time interval of the set time.
Carry current AC/DC (A)
±0.01% ±0.05 s max. (see note 1)
±15 s per month (at 25°C)
100 MΩ min.
2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying
metal parts and between control power supply circuit and contact control output circuits)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
Destruction: 300 m/s
Malfunction: 100 m/s
Operating:
Operating:
100,000 operations min. (15 A at 250 VAC, resistive load)
UL (File No. E52800), CSA (File No. LR22310)
Approx. 350 g
–10°C to 55°C
35% to 85%
2
2
(approx. 30G)
(approx. 10G)
H5L
2