10.1 Error Messages of PG-FP4 in Standalone Mode
106
001
005
006
009
011
012
013
020
021
022
023
024
025
030
032
040
041
042
043
050
051
The PG-FP4 error and warning messages are displayed on the message display.
No.
Invalid PRM data
Not supported !
Command aborted!
Power failure
Read. Sig failed
Check connection
Addr. Range err
Inv. Sig. ID
Inv. Sig. Code
Inv. Sig. func.
Inv. Sig. addr.
Inv. device name
Inv. Signature
Prewrite Timeout
Prewr. retry err
Erase Timeout
Erase failure
Ers time exceed
Ers Timeset err
Bln Timeout
Blankchk failed
Message
PRM data is invalid
Command aborted
Abnormal VDD current
Reading device signature failed
Check connection
Address range error
Invalid signature ID
Invalid signature code
Invalid signature function
Invalid signature address
Invalid device name
Invalid signature
Prewrite timeout
Prewrite retry error
Erase timeout
Erase failure
Erase time exceeded
Erase timeset error
Blank check timeout
Blank check failed
CHAPTER 10 ERROR MESSAGES
Error Condition
User’s Manual U15260EJ4V0UM
The parameter file includes invalid data, or the file
is incomplete.
Re-set using the parameter file downloaded from
the following URL.
http://www.necel.com/micro/ods/eng/index.html
The command issued is not supported on the
device and thus cannot be used.
An overcurrent was detected when VDD was
output. Check the connection with the device.
Check if the correct device is selected.
The PG-FP4 cannot establish connection to the
target device.
This might be due to wrong connections between
device and the PG-FP4, bad socket contacts or
non-working oscillator.
The address given in the command exceeds the
device’s address range.
Check if the correct device is selected.
Check if the correct device is selected.
Check if the correct device is selected.
Check if the correct device is selected.
Check if the correct device is selected.
Check if the correct device is selected.
Communication problem between the PG-FP4 and
the target device. Try the operation again.
Communication problem between the PG-FP4 and
the target device. Try the operation again.
A device defect is most probably causing this error.
A device defect is most probably causing this error.
The parameter file may contain invalid data.
Contact NEC Electronics.
Communication problem between the PG-FP4 and
the target device. Try the operation again.
The device connected is not empty. Use the ‘erase’
command before programming.
Possible Workaround