HS0005KCU01H Renesas Electronics America, HS0005KCU01H Datasheet - Page 33
HS0005KCU01H
Manufacturer Part Number
HS0005KCU01H
Description
ON CHIP DEBUG EMULATOR
Manufacturer
Renesas Electronics America
Type
In Circuit Debuggerr
Datasheets
1.HS0005KCU01H.pdf
(24 pages)
2.HS0005KCU01H.pdf
(45 pages)
3.HS0005KCU01H.pdf
(28 pages)
Specifications of HS0005KCU01H
Contents
E10T-USB, Cable and CD-ROM
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
H8S, H8SX, SH-2, SH-2A, SH3, SH4, SH4A & SH-Mobile
Lead Free Status / RoHS Status
Not Compliant, Contains lead / RoHS non-compliant
13. If an address of a BREAKPOINT cannot be correctly set in the ROM or flash memory area, a
2.2.5
1. When [Go to cursor], [Step In], [Step Over], or [Step Out] is selected, the settings of Break
2. Break Condition 2 is disabled when an instruction to which a BREAKPOINT has been set is
3. When a Break Condition is satisfied, emulation may stop after two or more instructions have
4. If a PC break address condition is set to the slot instruction after a delayed branch instruction,
5. Break Condition 1,2 is used as the measurement range in the performance measurement
6. A break will not occur with the execution counts specified on the execution of the multi-step
2.2.6
In the [Configuration] dialog box, if [User] is set while the [UBC mode] list box has been set, the
STEP-type commands that use Break Condition 2 for implementation cannot be used.
BREAKPOINT setting, the BREAKPOINT address remains unchanged. When a
BREAKPOINT is satisfied with the modified address in the VP_MAP table, the cause of
termination displayed in the status bar and the [Output] window is ILLEGAL INSTRUCTION,
not BREAKPOINT.
mark
window by refreshing the [Memory] window, etc. after Go execution. However, no break will
occur at this address. When the program halts with the break condition, the mark
disappears.
Condition 2 are disabled.
executed. Accordingly, do not set a BREAKPOINT to an instruction which satisfies Break
Condition 2.
been executed.
user program execution cannot be terminated before the slot instruction execution; execution
stops before the branch destination instruction.
function when [PA-1 start point] and [PA-1 end point] are displayed on the [Action] part in the
[Break condition] sheet of the [Eventpoint] window. This applies when the Break Condition is
displayed with the BREAKCONDITION_DISPLAY command in the command-line function.
In this case, a break does not occur when Break Condition 1,2 is satisfied.
instruction.
Notes on Setting the [Break Condition] Dialog Box and the BREAKCONDITION_
SET Command
Note on Setting the UBC_MODE Command
will be displayed in the [BP] area of the address on the [Source] or [Disassembly]
25