RDK-193 Power Integrations, RDK-193 Datasheet - Page 7

KIT REF DESIGN FOR LNK403EG

RDK-193

Manufacturer Part Number
RDK-193
Description
KIT REF DESIGN FOR LNK403EG
Manufacturer
Power Integrations
Type
Power Factor Correctionr
Datasheets

Specifications of RDK-193

Current - Output / Channel
330mA
Outputs And Type
1, Non-Isolated
Voltage - Output
21V
Features
Dimmable with Standard TRIAC Dimmer, Power Factor Correction
Voltage - Input
90 ~ 265VAC
Utilized Ic / Part
LNK403EG
Input Voltage
90 V to 265 V
Output Voltage
21 V
Product
Power Management Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
LNK403EG
Other names
596-1307

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RDK-193
Manufacturer:
Power Integrations
Quantity:
135
2 Power Supply Specification
The table below represents the minimum acceptable performance of the design. Actual
performance is listed in the results section.
Notes:
a
dimming range, the output current for a LinkSwitch-PH design varies with line voltage.
Therefore the output current specification is defined at a single line voltage only. For this
design a line voltage of 115 VAC was selected. At higher line voltages the output current
will increase and reduce with lower line voltages. The typical output current variation is
+30% for +200% increase in line voltage. A single resistor value change can be used to
center the nominal output current for a given nominal line voltage. See Table 1 for the
feedback resistor value vs. nominal line voltage.
b
heatsink to the LinkSwitch-PH device.
Page 7 of 41
Input
Voltage
Frequency
Output
Output Voltage
Output Current
Total Output Power
Continuous Output Power
Efficiency
Full Load
Environmental
Conducted EMI
Safety
Ring Wave (100 kHz)
Power Factor
Harmonics
Ambient Temperature
When configured for phase controlled (TRIAC) dimming, in order to give the widest
Maximum ambient temperature specification may be increased by adding a small
Differential Mode (L1-L2)
Common mode (L1/L2-PE)
a
Description
a
b
Symbol
T
V
P
f
I
V
LINE
OUT
AMB
OUT
OUT
IN
Min
Designed to meet IEC950 / UL1950
0.9
90
47
18
80
EN 61000-3-2 Class D
Meets CISPR 15B / EN55015B
50/60
0.33
Typ
115
2.5
21
40
7
Class II
Tel: +1 408 414 9200 Fax: +1 408 414 9201
Max
265
64
24
Units
VAC
Hz
kV
o
W
%
V
A
C
Power Integrations
V
Measured at V
www.powerint.com
OUT
Free convection, sea level
Measured at P
IEC 61000-4-5 , 200 A
= 21, V
and 115/230 VAC
2 Wire – no P.E.
Comment
IN
= 115 VAC, 25°C
OUT(TYP)
OUT
25
, I
OUT(TYP)
o
C