SI3461-KIT Silicon Laboratories Inc, SI3461-KIT Datasheet - Page 4

BOARD EVAL FOR SI3461

SI3461-KIT

Manufacturer Part Number
SI3461-KIT
Description
BOARD EVAL FOR SI3461
Manufacturer
Silicon Laboratories Inc
Type
Controllers & Processorsr
Datasheets

Specifications of SI3461-KIT

Main Purpose
Special Purpose DC/DC, Power Over Ethernet
Board Type
Fully Populated
Utilized Ic / Part
Si3461
Ethernet Connection Type
10/100 Base-T, IEEE 802.3
Interface Type
Ethernet
Operating Voltage
12 V to 15 V
Operating Current
10 mA
Product
Modules
For Use With/related Products
Si3460
Lead Free Status / RoHS Status
Lead free / RoHS non-compliant
Current - Output
-
Voltage - Output
-
Voltage - Input
-
Power - Output
-
Frequency - Switching
-
Outputs And Type
-
Regulator Topology
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1843
Si3460-EVB
4.2. Classification
Classification is optional and is performed by applying between 15.5 and 20.5 V to the PD and measuring the
current. The maximum power level that can be drawn by the PD is determined according the following table.
Currents not falling in these ranges maybe be treated as the higher or lower classification level. Currents above
45 mA may be treated as class level 0 or 4, which is 15.4 W in either case.
4.3. Power-Up
After the optional classification step, power is applied. Per the IEEE specification, the PSE must supply between 44
and 57 V to the PD. For longer durations above 50 ms the power may be removed if the maximum power level of
either 4, 7, or 15.4 W is exceeded. If the current exceeds 400 mA, the power must be removed in 75 ms. For
short-circuit protection, output power is removed immediately if the output current exceeds 800 mA or the output
voltage drops below 30 V. If power is removed due to an overload condition, detection must not be attempted again
for at least 2 s.
4.4. Disconnect (Power Removal)
The Si3460 supports a robust disconnect algorithm to avoid false disconnection. Removal of a PD can be sensed
by determining that the dc current is less than 5 mA for between 300 and 400 ms. If the current then exceeds
10 mA for at least 60 ms, the power must not be removed, and the 300–400 ms timer restarts.
4
Classification Level
Class 0
Class 1
Class 2
Class 3
Class 4
Table 1. Classification Levels
Minimum PSE Power Level
Rev. 1.1
15.4 W
15.4 W
15.4 W
4 W
7 W
Current Measured
16–21 mA
25–31 mA
35–45 mA
8–13 mA
<5 mA

Related parts for SI3461-KIT