MAX11068EVKIT+ Maxim Integrated Products, MAX11068EVKIT+ Datasheet - Page 78

no-image

MAX11068EVKIT+

Manufacturer Part Number
MAX11068EVKIT+
Description
KIT SMART BATT MEASUREMENT 12CH
Manufacturer
Maxim Integrated Products
Datasheets

Specifications of MAX11068EVKIT+

Main Purpose
Power Management, Battery Monitor, Car
Utilized Ic / Part
MAX11068
Primary Attributes
Monitors Current, Voltage, Temperature
Secondary Attributes
1 ~ 12 Cell- Li-Ion, 1 ~ 12 Cell- NiMH
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Embedded
-
12-Channel, High-Voltage Sensor, Smart
Data-Acquisition Interface
Table 40. Failure-Mode Effects Analysis
78
PIN
10
1
2
3
4
5
6
7
8
9
ALRM
NAME
GPIO2
GND
VDD
SDA
SCL
DCIN
CP+
N.C.
CP-
U
U
U
U
U
Open or
disconnected
Short to
pin 2
Open or
disconnected
Short to
pin 3
Open or
disconnected
Short to
pin 4
Open or
disconnected
Short to
pin 5
Open or
disconnected
Short to
pin 6
Open or
disconnected
Short to
pin 7
Open or
disconnected
Short to
pin 8
Open or
disconnected
Short to
pin 9
Open or
disconnected
Short to
pin 10
Open or
disconnected
Short to
pin 11
ACTION
I
ALRTCPUV of the FMEA register is set to 1. ALRTFMEA of the STATUS register is set to 1.
ALRTCPUV of the FMEA register is set to 1. ALRTFMEA of the STATUS register is set to 1.
ALRTCPUV of the FMEA register is set to 1. ALRTFMEA of the STATUS register is set to 1.
ALRTCPUV of the FMEA register is set to 1. ALRTFMEA of the STATUS register is set to 1.
ALRTCPUV of the FMEA register is set to 1. ALRTFMEA of the STATUS register is set to 1.
ALRTCPUV of the FMEA register is set to 1. ALRTFMEA of the STATUS register is set to 1.
ALRTCPUV of the FMEA register is set to 1. ALRTFMEA of the STATUS register is set to 1.
I
ALRTFMEA of the STATUS register is set to 1.
The up-device cell registers are read back all 1. ALRTACK of the STATUS register is set to
1. No effect for the single device or the top device.
The up-device cell registers are read back all 1. ALRTACK and ALRTPEC of the STATUS
register are set to 1. No effect for the single device or the top device.
The up-device cell registers are read back all 1. No effect for the single device or the top
device.
The up-device cell registers are read back all 1. ALRTACK of the STATUS register is set to
1. No effect for the single device or the top device.
ALRTPEC and ALRTACK of the STATUS register are set to 1. The up-device cell registers
are read back as the random number. No effect for the single device or the top device.
ALRTHBEAT of the FMEA register is set to 1. ALRTFMEA of the STATUS register is set to
1. No heartbeat. No effect for the single device or the top device.
No effect.
No effect.
No effect.
Lost the input status or no drive capability.
If both GPIO2 and GPIO1 are configured as the input or the same status for the output,
there is no effect. If they are configured as a different value as the output, it shows the
output of 0V and the part is reset.
2
2
C lost communication. No heartbeat.
C lost communication. No heartbeat. ALRTCPUV of the FMEA register is set to 1.
EFFECT

Related parts for MAX11068EVKIT+