Table 13. ADCCFG—ADC Configuration Register Description (Address 0x08)
D15
D14
D13
D12
D11
D10
BIT
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
ALRMMMTCHEN
ALRMOVEN
ALRMUVEN
ALRMUTEN
ALRMOTEN
ALRMACK
ALRMPEC
12-Channel, High-Voltage Sensor, Smart
DIAGEN
AIN2EN
AIN1EN
Unused
Unused
Unused
Unused
Unused
NAME
SCAN
Start conversions scan set with 1 to initiate an ADC scan of the enabled cell channels. A
new measurement scan is initiated as long as the ADC is not busy with a previous scan.
Otherwise, the scan start is ignored. This bit always reads back 0.
The SCAN bit of the SCANCTRL register has the same function and is the recommended
register control for initiating a scan.
Voltage Mismatch Alarm Enable Mask:
Set ALRMMMTCHEN = 1 to force a mismatch alert, ALRTMSMTCH, to generate an alarm.
Set ALRMMMTCHEN = 0 to prevent a mismatch alert from generating an alarm.
Overvoltage Alarm Enable Mask:
Set ALRMOVEN = 1 to force an overvoltage alert, ALRTOV, to generate an alarm. Set
ALRMOVEN = 0 to prevent an overvoltage alert from generating an alarm.
Undervoltage Alarm Enable Mask:
Set ALRMUVEN = 1 to force an undervoltage alert, ALRTUV, to generate an alarm. Set
ALRMUVEN = 0 to prevent an undervoltage alert from generating an alarm.
Undertemperature Alarm Enable Mask:
Set ALRMUTEN = 1 to force an undertemperature alert, ALRTTCOLD, to generate an alarm.
Set ALRMUTEN = 0 to prevent an undertemperature alert from generating an alarm.
Overtemperature Alarm Enable Mask:
Set ALRMOTEN = 1 to force an overtemperature alert, ALRTTHOT, to generate an alarm. Set
ALRMOTEN = 0 to prevent an overtemperature alert from generating an alarm.
Packet-Error Check (PEC) Alarm Enable Mask:
Set ALRMPEC = 1 to force a packet-error check alert, ALRTPEC, to generate an alarm. Set
ALRMPEC = 0 to prevent a packet-error check alert from generating an alarm.
Acknowledge Communication Fault Alarm Enable:
Set ALRMACK = 1 to force an acknowledge communication fault alert, ALRTACK, to
generate an alarm. Set ALRMACK = 0 to prevent an acknowledge communication check
alert from generating an alarm.
Unused Bit:
Reads back written value.
Self-Test Diagnostic Enable:
Enable reference channel diagnostic conversion. Used for internal diagnostic self-test. Set
to 1 to enable the measurement to occur during the measurement cycle.
Unused Bit:
Reads back written value.
AUXIN2 Channel Conversion Enable:
Enables a conversion on the AUXIN2 input. After a conversion is completed, the results are
compared to the over- and undertemperature thresholds.
AUXIN1 Channel Conversion Enable:
Enables a conversion on the AUXIN1 input. After a conversion is completed, the results are
compared to the over- and undertemperature thresholds.