Table 16. BALCFG—Cell-Balancing Configuration Register Description (Address 0x0B)
Table 17. ACQCFG—Acquisition Configuration Register Description (Address 0x0C)
D15
D14
D13
D12
D11
D10
BIT
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
D15
D14
D13
D12
D11
D10
BIT
D9
D8
D7
D6
12-Channel, High-Voltage Sensor, Smart
CBTIMER3
CBTIMER2
CBTIMER1
CBTIMER0
NAME
BAL12
BAL11
BAL10
CBPDIV1
CBPDIV0
BAL9
BAL8
BAL7
BAL6
BAL5
BAL4
BAL3
BAL2
BAL1
NAME
0
0
0
0
0
0
0
0
Write ignored; read back 0.
Cell-Balancing/Discharge Switch Enable:
Select cell-balancing/discharge switches to activate. Set BAL[N] to 1 to enable the cell-
balancing switch between C
switch. The switches are separately disabled by signals from the die overtemperature
detection circuit and the cell-balancing watchdog timer.
Write ignored; read back 0.
Cell-Balancing Timer Predivider:
Sets the step size of the cell-balancing timer LSB.
00 = Disabled, no timeout for the cell-balancing switch on-time.
01 = 1s; timer range is then 1s to15s.
10 = 4s; timer range is then 4s to 60s.
11 = 16s; timer range is then 16s to 240s.
Cell-Balancing Timer:
Acts as a safety watchdog timeout for the cell-balancing switches. The timer counts down
at a rate set by the CBPDIV bits. When the timer reaches 0, all cell-balancing switches are
disabled. The timer should be periodically rewritten with a timeout value to keep the cell-
balancing switches enabled. When the timer value is read, the value reported is latched
during the 9th bit time following the ACQCFG register address of the READALL command.
Write ignored; read back 0.
Data-Acquisition Interface
N-1
and C
N.
FUNCTION
Clearing to 0 disables the balancing/discharge
FUNCTION
43