CDB42428 Cirrus Logic Inc, CDB42428 Datasheet - Page 47

no-image

CDB42428

Manufacturer Part Number
CDB42428
Description
BOARD EVAL FOR CS42428 CODEC
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CDB42428

Main Purpose
Audio, CODEC
Embedded
Yes, FPGA / CPLD
Utilized Ic / Part
CS42428/26/18/16
Primary Attributes
6 Single-Ended Analog Inputs and 8 Outputs, S/PDIF Digital Audio Transmitter and Receiver
Secondary Attributes
Graphic User Interface
Product
Audio Modules
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
598-1499
DS605F1
6.6.4
6.6.5
6.6.6
6.6.7
INTERPOLATION FILTER SELECT (FILT_SEL)
HIGH-PASS FILTER FREEZE (HPF_FREEZE)
DAC SERIAL PORT MASTER/SLAVE SELECT (DAC_SP M/S)
ADC SERIAL PORT MASTER/SLAVE SELECT (ADC_SP M/S)
Default = 0
Function:
Default = 0
Function:
Default = 0
Function:
Default = 0
Function:
This feature allows the user to select whether the DAC interpolation filter has a fast- or slow roll-off.
For filter characteristics, please See
0 - Fast roll-off.
1 - Slow roll-off.
When this bit is set, the internal high-pass filter for the selected channel will be disabled. The current
DC offset value will be frozen and continue to be subtracted from the conversion result. See
ital Filter Characteristics” on page
In Master Mode, DAC_SCLK and DAC_LRCK are outputs. Internal dividers will divide the master
clock to generate the serial clock and left/right clock. In Slave Mode, DAC_SCLK and DAC_LRCK
become inputs.
If the DAC_SP is in Slave Mode, DAC_LRCK must be present for proper device operation.
In Master Mode, ADC_SCLK and ADC_LRCK are outputs. Internal dividers will divide the master
clock to generate the serial clock and left/right clock. In Slave Mode, ADC_SCLK and ADC_LRCK
become inputs.
If the ADC_SP is in Slave Mode, ADC_LRCK must be present for proper device operation.
To use the PLL to lock to ADC_LRCK, the ADC_SP must be in Slave Mode. When using the PLL to
lock to LRCK, if ADC_SDOUT is configured to be clocked by the ADC_SP, both ADC_SCLK and
ADC_LRCK must be present. If ADC_SDOUT is configured to be clocked by the DAC_SP, only the
ADC_LRCK signal must be applied.
8.
“D/A Digital Filter Characteristics” on page
10.
CS42428
“A/D Dig-
47