MCP3909RD-3PH1 Microchip Technology, MCP3909RD-3PH1 Datasheet - Page 55

REF DESIGN MCP3909 3PH ENGY MTR

MCP3909RD-3PH1

Manufacturer Part Number
MCP3909RD-3PH1
Description
REF DESIGN MCP3909 3PH ENGY MTR
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP3909RD-3PH1

Main Purpose
Power Management, Energy/Power Meter
Embedded
No
Utilized Ic / Part
MCP3909, PIC18F2520, PIC18F4550
Primary Attributes
3-Ph, 220 VAC, In Case, LCD, USB, GUI
Secondary Attributes
Opto-Isolated Interface for Safety
Operating Voltage
220 V
Operating Current
5 A
Description/function
Energy Meter
For Use With/related Products
MCP3909
Lead Free Status / RoHS Status
Not applicable / Not applicable
© 2008 Microchip Technology Inc.
5.3.9
For active power offset the following equations apply for a given phase. W1 corre-
sponds to the PHy_W_RAW register obtained during configuration C1. LINE_CYC_W1
corresponds to the LINE_CYC during this measurement.
W2 corresponds to the PHy_W_RAW register obtained during configuration C3.
LINE_CYC_W2 is the LINE_CYC during this measurement.
EQUATION 5-16:
EQUATION 5-17:
EQUATION 5-18:
EQUATION 5-19:
EQUATION 5-20:
The PHy_W_OFF registers hold a signed 32-bit value. However, the math in the
microcontroller could overflow for some values near the limits. Limit check the resulting
value to make sure the value is between -2,130,706,432 and 2,130,706,431 (inclusive).
Values less than -2,130,706,432 should be set to -2,130,706,432 while values greater
than 2,130,706,431 should be set to 2,130,706,431. If the value is limited, the user
should be aware that the meter could not completely correct the offset.
It is expected that this value will always be negative. If the value is positive, it may
indicate that the user has not provided a large enough number of line cycles for
configuration C4 (where the number of line cycles should be set to a larger value such
as 64 or 128). This may also be true if offset does not contribute a large enough
percentage to W2 (for example, 10% to 50% or more).
Note:
PHY_W_OFF
LINE_CYC_NUM_1
LINE_CYC_NUM_2
Equations for Active Power Offset Calibration
Convert to 32-bit signed integer for compatibility with 18F2520 register and
firmware calculations
W2
W1
=
PHY_W_RAW @ 1/100 I
=
=
PHY_W_RAW @ I
----------------------------------------------------- -
LINE_CYC_NUM_W1
=
=
W1 100
LINE_CYC_NUM in Configuration C1
LINE_CYC_NUM in Configuration C3
B,
Configuration C1
B
, Configuration C3
Meter Calibration
----------------------------------------------------- -
LINE_CYC_NUM_W2
W2
DS51643B-page 51

Related parts for MCP3909RD-3PH1