MCP3909RD-3PH1 Microchip Technology, MCP3909RD-3PH1 Datasheet - Page 26

REF DESIGN MCP3909 3PH ENGY MTR

MCP3909RD-3PH1

Manufacturer Part Number
MCP3909RD-3PH1
Description
REF DESIGN MCP3909 3PH ENGY MTR
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP3909RD-3PH1

Main Purpose
Power Management, Energy/Power Meter
Embedded
No
Utilized Ic / Part
MCP3909, PIC18F2520, PIC18F4550
Primary Attributes
3-Ph, 220 VAC, In Case, LCD, USB, GUI
Secondary Attributes
Opto-Isolated Interface for Safety
Operating Voltage
220 V
Operating Current
5 A
Description/function
Energy Meter
For Use With/related Products
MCP3909
Lead Free Status / RoHS Status
Not applicable / Not applicable
MCP3909 3-Phase Energy Meter Reference Design
3.4.2
DS51643B-page 22
bit 15
bit 7
Legend:
R = Readable bit
-n = Value at POR
bit 15-3
bit 2
bit 1
bit 0
U-0
U-0
STATUS1 Register
Unimplemented: Read as ‘0’
PHA_S: Phase A Sign Bit.
(if enabled, see MODE1 bits).
1
0
PHB_S: Phase B Sign Bit.
(if enabled, see MODE1 bits).
1
0
PHC_S: Phase C Sign Bit.
(if enabled, see MODE1 bits).
1
0
=
= Operation Normal
=
= Operation Normal
=
= Operation Normal
U-0
U-0
Negative active power, this may indicate the CT is wired in backwards
Negative active power, this may indicate the CT is wired in backwards
Negative active power, this may indicate the CT is wired in backwards
REGISTER 3-2:
The STATUS1 register contains the operational status of the energy meter. The bit
functions are defined by the table below.
STATUS1
Name
W = Writable bit
‘1’ = Bit is set
U-0
U-0
Bits
16
This is the sign bit of raw active power before absolute value taken
This is the sign bit of raw active power before absolute value taken
This is the sign bit of raw active power before absolute value taken
STATUS1 Register
U-0
U-0
Address
0x004
U = Unimplemented bit, read as ‘0’
‘0’ = Bit is cleared
U-0
U-0
Cof
R
PHA_S
U-0
R
© 2008 Microchip Technology Inc.
x = Bit is unknown
PHB_S
U-0
R
PHC_S
U-0
R
bit 8
bit 0

Related parts for MCP3909RD-3PH1