MCP3909RD-3PH1 Microchip Technology, MCP3909RD-3PH1 Datasheet - Page 52

REF DESIGN MCP3909 3PH ENGY MTR

MCP3909RD-3PH1

Manufacturer Part Number
MCP3909RD-3PH1
Description
REF DESIGN MCP3909 3PH ENGY MTR
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP3909RD-3PH1

Main Purpose
Power Management, Energy/Power Meter
Embedded
No
Utilized Ic / Part
MCP3909, PIC18F2520, PIC18F4550
Primary Attributes
3-Ph, 220 VAC, In Case, LCD, USB, GUI
Secondary Attributes
Opto-Isolated Interface for Safety
Operating Voltage
220 V
Operating Current
5 A
Description/function
Energy Meter
For Use With/related Products
MCP3909
Lead Free Status / RoHS Status
Not applicable / Not applicable
MCP3909 / dsPIC33F 3-Phase Energy Meter Reference Design
6.2
6.3
DS51723A-page 52
TEST CONNECTION COMMAND
TOTAL DATA REQUEST
Variant-length frame structure is used and data communiate in bytes. The command
protocol structure is defined as following.
TABLE 6-2:
• The START word has 2 bytes, which are 0x00, 0xFF ( PC to target board) or 0xFF,
• Command word is 1 byte which indicates the type of the command
• Data length word is 1 byte that indicates the length of data field
• The data field word has multiple byte(s) that varies with command types
• Checksum word is a single byte, whose content equals to the XOR value of all
• Stop word is 1 byte with the content of 0xE0
This command is sent from the PC to the meter to setup and test the connection.
TABLE 6-3:
TABLE 6-4:
This is the main command retrieves all the calcuated data from the dsPIC33F. This
command gathers data from all 3 phases including total energy, power, and power
factor data.
TABLE 6-5:
TABLE 6-6:
0xFF, 0x00
0xFF, 0x00
0xFF, 0x00
0xFF, 0x00
0x00 (target board to PC)
bytes sent before it
2 Bytes
START
START
START
START
START
Command
Command
Command
Command
Command
1 Bytes
TYPICAL PROTOTOL
PC TO METER (7 BYTES)
METER RESPONSE (8 BYTES)
PC TO METER (7 BYTES)
METER RESPONSE (104 BYTES)
0x41
0x42
0x42
0x43
Length
Length
Length
Length
Length
1 Byte
Data
Data
0x00
Data
0x02
Data
0x00
Data
0x62
0xA5, 0X5A
Data Field
Data Field
Data Field
Data Field
Data Field
98 bytes
N Bytes
0x00
0x00
Check Sum
Check Sum
Check Sum
Check Sum
Check Sum
© 2009 Microchip Technology Inc.
1 Byte
XX
XX
XX
XX
1 Byte
STOP
STOP
STOP
STOP
STOP
0xE0
0xE0
0xE0
0xE0

Related parts for MCP3909RD-3PH1