MCP3909RD-3PH1 Microchip Technology, MCP3909RD-3PH1 Datasheet - Page 14

REF DESIGN MCP3909 3PH ENGY MTR

MCP3909RD-3PH1

Manufacturer Part Number
MCP3909RD-3PH1
Description
REF DESIGN MCP3909 3PH ENGY MTR
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP3909RD-3PH1

Main Purpose
Power Management, Energy/Power Meter
Embedded
No
Utilized Ic / Part
MCP3909, PIC18F2520, PIC18F4550
Primary Attributes
3-Ph, 220 VAC, In Case, LCD, USB, GUI
Secondary Attributes
Opto-Isolated Interface for Safety
Operating Voltage
220 V
Operating Current
5 A
Description/function
Energy Meter
For Use With/related Products
MCP3909
Lead Free Status / RoHS Status
Not applicable / Not applicable
MCP3909 / dsPIC33F 3-Phase Energy Meter Reference Design
DS51723A-page 14
Step 1: Connect the meter to 220V line and load
The diagram below shows where the voltage and current connections should be made.
It is not required to connect all 3 phases for the meter to be operational.
220VAC should be placed between either V
The AC load for a given phase should then be connected to the I
phase.
FIGURE 1-2:
Step 2: Turn On Line/Load Power to the Meter
Turn on the power to the energy meter. D1 should be lit showing the meter has power.
At this point, if a load is connected and the meter is measuring power, the power LED,
D1, should be blinking.
IA
IN
VA
Meter Case Bottom.
IA
OUT
IB
IN
VB
IB
A
, V
OUT
B
, V
C
IC
and N
IN
VC
© 2009 Microchip Technology Inc.
IN
, N
IC
IN
OUT
OUT
and I
.
OUT
of a given

Related parts for MCP3909RD-3PH1