STEVAL-ISF001V1 STMicroelectronics, STEVAL-ISF001V1 Datasheet - Page 30

BOARD EVAL FOR L6563/STW55NM60N

STEVAL-ISF001V1

Manufacturer Part Number
STEVAL-ISF001V1
Description
BOARD EVAL FOR L6563/STW55NM60N
Manufacturer
STMicroelectronics
Type
MOSFET & Power Driverr

Specifications of STEVAL-ISF001V1

Main Purpose
Power Management, Power Factor Correction
Embedded
No
Utilized Ic / Part
L6563
Primary Attributes
3 kW, 400 V Out, FOT(Fixed Off Time Control), 240 VAC (185 ~ 265 Vrms)
Secondary Attributes
Iout Max 7.5 A
Product
Power Management Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
STW55NM60N
Other names
497-8850
Application information
30/39
Figure 44. Interface circuits that let the L6563/A switch on or off a PWM controller
If this is not the case or it is not possible to achieve a start-up delay long enough (because
this prevents the DC-DC stage from starting up correctly) or, simply, the PWM controller is
devoid of soft start, the arrangement of
the voltage generated by the PFC stage reaches a preset value. The technique relies on the
UVLO thresholds of the PWM controller.
Figure 45. Interface circuits for actual power-up sequencing (master PFC)
Another possible use of the RUN and PWM_STOP pins (again, in systems where the PFC
stage is the master) is brownout protection, thanks to the hysteresis provided.
Brownout protection is basically a not-latched device shutdown function that must be
activated when a condition of mains undervoltage is detected. This condition may cause
overheating of the primary power section due to an excess of RMS current. Brownout can
also cause the PFC pre-regulator to work open loop and this could be dangerous to the PFC
stage itself and the downstream converter, should the input voltage return abruptly to its
rated value. Another problem is the spurious restarts that may occur during converter power
down and that cause the output voltage of the converter not to decay to zero monotonically.
For these reasons it is usually preferable to shutdown the unit in case of brownout.
Figure 45
lets the DC-DC converter start-up when
L6563 - L6563A

Related parts for STEVAL-ISF001V1