MAP80-1024 POWER ONE, MAP80-1024 Datasheet - Page 3

PWR SUPPLY SNG OUTPUT ADJ 24-28V

MAP80-1024

Manufacturer Part Number
MAP80-1024
Description
PWR SUPPLY SNG OUTPUT ADJ 24-28V
Manufacturer
POWER ONE
Series
MAP80r
Type
Commercial, Industrialr
Datasheet

Specifications of MAP80-1024

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
80W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
110 ~ 220VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 3.8A
Size / Dimension
7.2" L x 4.2" W x 1.8" H (182.9mm x 106.7mm x 45.7mm)
Power (watts) - Rated
90W
Operating Temperature
0°C ~ 50°C
Efficiency
75%
Approvals
CE, CSA, EN, TUV, UL
Line Regulation
0.1%
Load Regulation
0.5%
Product
Switching
Commercial/medical
Commercial
Output Power Rating
90 W
Input Voltage
90 VAC to 264 VAC
Output Voltage (channel 1)
24 V, 28 V
Output Current (channel 1)
3.8 A, 3.2 A
Mounting Style
Chassis
Dimensions
7.2 in L x 4.2 in W x 1.8 in H
Brand/series
MAP80 Series
Configuration
Open-Frame
Current, Input
2.5 A (RMS)(90 VAC), 1.8 A (RMS)(110 VAC)
Current, Output
3.8⁄3.2 A (Max.)
Frequency, Operating
47 to 63 Hz (AC Input), 22 to 120 kHz (Operating)
Operation
Switching
Output
24 VDC @ 3.8 A/28 VDC @ 3.2 A
Power, Output
80 W
Power, Rating
80 W
Primary Type
AC-DC
Special Features
TTL Compatible Power Fail Signal
Voltage, Input
90 to 135/175 to 264 VAC
Voltage, Output
24/28 VDC
En61000-4-2 Esd Level 4 (8 Kv)
All Map Products
En61000-4-3 Radiated Level 3 (10 V/m)
All Map Products
Universal Input
90-132 VAC or 175-264 VAC
Output Current (max)
3.8/3.2A
Output Voltage
24/28V
Output Power (max)
80W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Length (mm)
182.9mm
Product Height (mm)
45.7mm
Product Depth (mm)
106.7mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Pin Count
14
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Q1167112
MCD10144 Rev. 1.0, 02-Feb-10
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand
Voltage
Electromagnetic
Interference,
Conducted
Input Transient
Protection
Insulation Resistance
Leakage Current
Environmental Specifications
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
Options
DESCRIPTION
Cover
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TUV).
Input to output.
FCC CFR title 47 part 15 sub-part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
EN61000-4-5 level 3.
Input to output.
Per EN60950, 264VAC.
CONDITIONS/DESCRIPTION
Operating.
Non-operating.
Derate linearly above 50°C by 2.5% per °C
to a maximum temperature of 70°C.
0°C to 70°C (After 15 minute warm-up).
Non-condensing.
Operating, peak acceleration.
Random vibration, 10Hz to 2kHz, 3 axis.
NOTES
Add ‘C’ suffix to model number or order part number 412-59585-G separately.
For convection cooled applications, derate output power to 65 watts on all multiple
output models and MAP80-1005. Derate MAP80-1012 and MAP80-1024 to 75 watts.
Page 3 of 4
MAP80 AC-DC Series Data Sheet
Line to ground
At 100% load:
At 50% load:
Line to line
2600
MIN
MIN
-55
B
B
B
1
7
0
0
5
(183.0mm x 107.0mm x 52.0mm)
±0.02
NOM
NOM
7.20" x 4.20" x 2.05"
2
www.power-one.com
Approved
SIZE IMPACT
±0.03
MAX
500
MAX
10k
40k
50
70
85
95
20
6
ASL Ft.
ASL Ft.
Class
UNITS
UNITS
%/°C
%RH
G
VDC
M
µA
kV
°C
°C
°C
RMS
G