MAP80-1024 POWER ONE, MAP80-1024 Datasheet - Page 2

PWR SUPPLY SNG OUTPUT ADJ 24-28V

MAP80-1024

Manufacturer Part Number
MAP80-1024
Description
PWR SUPPLY SNG OUTPUT ADJ 24-28V
Manufacturer
POWER ONE
Series
MAP80r
Type
Commercial, Industrialr
Datasheet

Specifications of MAP80-1024

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
80W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
110 ~ 220VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 3.8A
Size / Dimension
7.2" L x 4.2" W x 1.8" H (182.9mm x 106.7mm x 45.7mm)
Power (watts) - Rated
90W
Operating Temperature
0°C ~ 50°C
Efficiency
75%
Approvals
CE, CSA, EN, TUV, UL
Line Regulation
0.1%
Load Regulation
0.5%
Product
Switching
Commercial/medical
Commercial
Output Power Rating
90 W
Input Voltage
90 VAC to 264 VAC
Output Voltage (channel 1)
24 V, 28 V
Output Current (channel 1)
3.8 A, 3.2 A
Mounting Style
Chassis
Dimensions
7.2 in L x 4.2 in W x 1.8 in H
Brand/series
MAP80 Series
Configuration
Open-Frame
Current, Input
2.5 A (RMS)(90 VAC), 1.8 A (RMS)(110 VAC)
Current, Output
3.8⁄3.2 A (Max.)
Frequency, Operating
47 to 63 Hz (AC Input), 22 to 120 kHz (Operating)
Operation
Switching
Output
24 VDC @ 3.8 A/28 VDC @ 3.2 A
Power, Output
80 W
Power, Rating
80 W
Primary Type
AC-DC
Special Features
TTL Compatible Power Fail Signal
Voltage, Input
90 to 135/175 to 264 VAC
Voltage, Output
24/28 VDC
En61000-4-2 Esd Level 4 (8 Kv)
All Map Products
En61000-4-3 Radiated Level 3 (10 V/m)
All Map Products
Universal Input
90-132 VAC or 175-264 VAC
Output Current (max)
3.8/3.2A
Output Voltage
24/28V
Output Power (max)
80W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Length (mm)
182.9mm
Product Height (mm)
45.7mm
Product Depth (mm)
106.7mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Pin Count
14
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Q1167112
Multiple Output Model Selection (Cont.)
MAP80-4010
MAP80-4020
NOTES:
MCD10144 Rev. 1.0, 02-Feb-10
Input Specifications
PARAMETER
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
Output Specifications
PARAMETER
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-On Delay
Turn-on Rise Time
Interface Signals and Internal Protection
PARAMETER
Overvoltage
Protection
Overload Protection
Power Fail
Warning (Note 1)
NOTES:
MODEL
Model numbers highlighted in yellow or shaded are not recommended for new designs.
1) Peak loads up to 90 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 90 Watts.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
1) Power Fail Warning is not available on MAP80-1024. The MAP80-1012 is an open collector output, capable of sinking 35 mA, maximum.
VOLTAGE
OUTPUT
+12V
+12V
-12V
-12V
+5V
+5V
-5V
-5V
11.52V to 12.48V
11.52V to 12.48V
4.8V to 5.5V
4.8V to 5.5V
CONDITIONS/DESCRIPTION
Continuous input range.
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC input voltage (115VAC), full rated load.
90 VAC (80W load).
110VAC (80W load).
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C.
Switching frequency of power supply (varies with load).
CONDITIONS/DESCRIPTION
Full load, 115VAC. Varies with distribution of loads among outputs.
MAP80-1012
MAP80-1024
MAP80-1005 and all multiple output models, main channel only.
Full load, 20MHz bandwidth.
Continuous output power, all multiple output models.
Peak output power (60s maximum, 10% duty cycle), all multiple output models.
Output voltage overshoot/undershoot at turn-on, V1, V2.
Varies by output. Total regulation includes: line changes from 90-132 VAC
or 175-264, changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output of multiple output units).
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
CONDITIONS/DESCRIPTION
Provided on MAP80-1005 and the main output of multiple output units.
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
TTL compatible logic signal. Time before regulation dropout
due to loss of input power at 110VAC.
ADJUSTMENT
RANGE
Fixed
Fixed
Fixed
Fixed
CURRENT
OUTPUT
14A
14A
4A
1A
3A
4A
1A
3A
80W Continuous Output Power
Page 2 of 4
CURRENT (NOTE 1)
PEAK OUTPUT
16A
16A
7A
1A
3A
7A
1A
3A
MAP80 AC-DC Series Data Sheet
REGULATION
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
LINE
MAP80-1012
MAP80-1024
REGULATION
LOAD
1%
1%
2%
2%
1%
1%
2%
2%
0.42
0.21
1.00
175
MIN
MIN
MIN
5.5
90
47
90
20
22
73
17
32
1
4
RIPPLE & NOISE
%p-p (NOTE 2)
1%
1%
1%
1%
1%
1%
1%
1%
NOM
NOM
NOM
75
See Model Selection Chart.
See Model Selection Chart.
www.power-one.com
-11.5V to -12.5V
-11.5V to -12.5V
MAX
135
264
120
MAX
500
MAX
2.5
1.8
6.8
45
80
80
90
12.0V to 12.1V
12.0V to 12.1V
63
20
23
37
-4.8V to -5.4V
-4.8V to -5.4V
1
5
INITIAL SETTING
5.1V to 5.2V
5.1V to 5.2V
ACCURACY
Amps
Watts
Watts
UNITS
A
UNITS
UNITS
VAC
VAC
A
kHz
Sec
mS
mS
mS
Hz
µS
RMS
%
%
V
PK