MAP80-4002 POWER ONE, MAP80-4002 Datasheet

MULTIPLE OUTPUT MODEL: 80W CONTINUOUSOUTPUT POWER

MAP80-4002

Manufacturer Part Number
MAP80-4002
Description
MULTIPLE OUTPUT MODEL: 80W CONTINUOUSOUTPUT POWER
Manufacturer
POWER ONE
Type
Commercial, Industrialr
Datasheet

Specifications of MAP80-4002

Product
Switching
Commercial/medical
Commercial
Output Power Rating
70 W
Input Voltage
90 VAC to 264 VAC
Number Of Outputs
4
Output Voltage (channel 1)
5 V
Output Current (channel 1)
14 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
4 A
Output Voltage (channel 3)
- 12 V
Output Current (channel 3)
1 A
Mounting Style
Chassis
Dimensions
7.2 in L x 4.2 in W x 1.8 in H
Brand/series
MAP80 Series
Configuration
Open-Frame
Current, Input
2.5 A (RMS) @ 90 VAC⁄1.8 A (RMS) @ 110 VAC
Current, Leakage
500 μA (Max.)
Hold Time
20 ms (Min.) @ 115 VAC (Nom.)
Mounting Type
Panel
Operation
Switching
Output
-12 VDC @ 1 A, +5 VDC @ 14 A, +12 VDC @ 4 A, +12 VDC @ 1 A
Power, Output
80 W
Power, Rating
80 W (Continuous)
Primary Type
AC-DC
Special Features
TTL Compatible Power Fail Signal
Temperature, Operating
0 to 50 °C @ 100% Load
Voltage, Input
90 to 135/175 to 264 VAC
Voltage, Output
-12, +5, +12, +12 VDC
Voltage, Output 1
-5 V
Voltage, Output 2
-5 V
Voltage, Output 3
12 V
Voltage, Output 4
-12 V
En61000-4-2 Esd Level 4 (8 Kv)
All Map Products
En61000-4-3 Radiated Level 3 (10 V/m)
All Map Products
Universal Input
90-132 VAC or 175-264 VAC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Description
Multiple Output Model Selection –
MCD10144 Rev. 1.0, 02-Feb-10
Single Output Model Selection
MAP80-1005
MAP80-1012
MAP80-1024
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
Power-One’s MAP80 Series of power supplies provides reliable, tightly-regulated DC power for commercial and
industrial systems which require high peak current capabilities. Wide-range AC input and full international safety, EMI,
and ESD compliance ensure worldwide acceptance. All units bear the CE Mark.
The MAP80 utilizes a variable frequency design with a thermally efficient U-channel chassis to provide full power
operation in convection-cooled applications. Design innovations include metric and SAE mounting inserts on each
mounting surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections
or popular single-row Molex connector mating.
Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific
output voltage requirements.
MODEL
MAP80-4000
MAP80-4001
MAP80-4002
MAP80-4003
MAP80-4004
MODEL
Model numbers highlighted in yellow or shaded are not recommended for new designs.
2) MAP80-1012 output currents are expressed as 12V/15V operation. MAP80-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
12V/15V
24V/28V
VOLTAGE
VOLTAGE
OUTPUT
OUTPUT
+12V
+24V
+12V
+12V
+12V
+15V
+24V
+15V
-12V
-12V
-12V
-15V
-15V
+5V
+5V
+5V
+5V
+5V
-5V
-5V
5V
11.52V to 12.48V
23.04V to 24.96V
11.52V to 12.48V
14.40V to 15.60V
23.04V to 24.96V
11.5V to 15.5V
23.0V to 29.0V
4.5V to 5.6V
ADJUSTMENT
4.8V to 5.5V
4.8V to 5.5V
4.7V to 5.5V
4.8V to 5.5V
4.8V to 5.5V
ADJUSTMENT
RANGE
RANGE
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
80W Continuous Output Power
3.8/3.2A (Note 2)
7.5/6A (Note 2)
MAXIMUM OUTPUT
CURRENT
CURRENT
OUTPUT
16A
3.5A
14A
14A
14A
14A
14A
4A
1A
1A
2A
1A
1A
4A
1A
1A
1A
1A
2A
1A
1A
Page 1 of 4
9.2/7.3A (Note 2)
4.6/3.9A (Note 2)
CURRENT (NOTE 1)
CURRENT (NOTE 3)
PEAK OUTPUT
PEAK OUTPUT
3.5A
3.5A
16A
16A
16A
16A
16A
7A
1A
1A
1A
1A
7A
1A
1A
6A
1A
1A
1A
1A
18A
Features
• RoHS lead-solder-exemption compliant
• Wide-range input for 110/220 VAC applications
• CE marked to Low Voltage Directive
• Input transient & ESD compliance to
• Meets EN55022, Class B limits
• TTL compatible Power Fail Signal
• Greater than 175,000 Hours MTBF
• Metric and SAE mounting inserts
MAP80 AC-DC Series Data Sheet
EN61000-4-2/-3/-4
REGULATION
REGULATION
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
LINE
0.2%
0.2%
0.1%
LINE
REGULATION
REGULATION
0.5%
±1%
LOAD
LOAD
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
RIPPLE & NOISE
%p-p (NOTE 2)
RIPPLE & NOISE
%p-p (NOTE 1)
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1.4%
0.5%
1%
www.power-one.com
-11.5V to -12.5V
-11.5V to -12.5V
-11.6V to -12.4V
-14.4V to -15.5V
-14.4V to -15.5V
11.9V to 12.1V
24.0V to 24.1V
11.5V to 12.5V
12.0V to 12.1V
11.6V to 12.4V
14.6V to 15.1V
24.0V to 24.1V
14.4V to 15.5V
11.76V to 12.15V
-4.8V to -5.4V
-4.8V to -5.4V
INITIAL SETTING
23.8V to 24.2V
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
INITIAL SETTING
5.0V to 5.1V
ACCURACY
ACCURACY

Related parts for MAP80-4002

MAP80-4002 Summary of contents

Page 1

... MAP80-4000 -5V Fixed -12V Fixed +5V 4.8V to 5.5V +24V 23.04V to 24.96V MAP80-4001 -12V Fixed +12V Fixed +5V 4.7V to 5.5V +12V 11.52V to 12.48V MAP80-4002 -12V Fixed +12V Fixed +5V 4.8V to 5.5V +15V 14.40V to 15.60V MAP80-4003 -5V Fixed -15V Fixed +5V 4.8V to 5.5V +24V 23.04V to 24.96V MAP80-4004 ...

Page 2

... TTL compatible logic signal. Time before regulation dropout Warning (Note 1) due to loss of input power at 110VAC. NOTES: 1) Power Fail Warning is not available on MAP80-1024. The MAP80-1012 is an open collector output, capable of sinking 35 mA, maximum. MCD10144 Rev. 1.0, 02-Feb-10 MAP80 AC-DC Series Data Sheet – ...

Page 3

... Add ‘C’ suffix to model number or order part number 412-59585-G separately. For convection cooled applications, derate output power to 65 watts on all multiple output models and MAP80-1005. Derate MAP80-1012 and MAP80-1024 to 75 watts. MCD10144 Rev. 1.0, 02-Feb-10 MAP80 AC-DC Series Data Sheet ...

Page 4

... Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10144 Rev. 1.0, 02-Feb-10 MAP80 AC-DC Series Data Sheet WEIGHT: 1.8 LBS (0.82 kg) Page www.power-one.com ...

Related keywords