MAP80-4003C POWER ONE, MAP80-4003C Datasheet

no-image

MAP80-4003C

Manufacturer Part Number
MAP80-4003C
Description
Linear & Switching Power Supplies W/COVER 80W,5V,14A 15V 3.5A/ -5V 1A
Manufacturer
POWER ONE
Datasheet

Specifications of MAP80-4003C

Product
Switching
Commercial/medical
Commercial
Output Power Rating
70 W
Input Voltage
90 VAC to 135 VAC, 175 VAC to 264 VAC
Number Of Outputs
4
Output Voltage (channel 1)
5 V
Output Current (channel 1)
14 A
Output Voltage (channel 2)
15 V
Output Current (channel 2)
3.5 A
Output Voltage (channel 3)
- 5 V
Output Current (channel 3)
1 A
Mounting Style
Chassis
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Description
Multiple Output Model Selection –
MCD10144 Rev. 1.0, 02-Feb-10
Single Output Model Selection
MAP80-1005
MAP80-1012
MAP80-1024
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
Power-One’s MAP80 Series of power supplies provides reliable, tightly-regulated DC power for commercial and
industrial systems which require high peak current capabilities. Wide-range AC input and full international safety, EMI,
and ESD compliance ensure worldwide acceptance. All units bear the CE Mark.
The MAP80 utilizes a variable frequency design with a thermally efficient U-channel chassis to provide full power
operation in convection-cooled applications. Design innovations include metric and SAE mounting inserts on each
mounting surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections
or popular single-row Molex connector mating.
Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific
output voltage requirements.
MODEL
MAP80-4000
MAP80-4001
MAP80-4002
MAP80-4003
MAP80-4004
MODEL
Model numbers highlighted in yellow or shaded are not recommended for new designs.
2) MAP80-1012 output currents are expressed as 12V/15V operation. MAP80-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
12V/15V
24V/28V
VOLTAGE
VOLTAGE
OUTPUT
OUTPUT
+12V
+24V
+12V
+12V
+12V
+15V
+24V
+15V
-12V
-12V
-12V
-15V
-15V
+5V
+5V
+5V
+5V
+5V
-5V
-5V
5V
11.52V to 12.48V
23.04V to 24.96V
11.52V to 12.48V
14.40V to 15.60V
23.04V to 24.96V
11.5V to 15.5V
23.0V to 29.0V
4.5V to 5.6V
ADJUSTMENT
4.8V to 5.5V
4.8V to 5.5V
4.7V to 5.5V
4.8V to 5.5V
4.8V to 5.5V
ADJUSTMENT
RANGE
RANGE
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
80W Continuous Output Power
3.8/3.2A (Note 2)
7.5/6A (Note 2)
MAXIMUM OUTPUT
CURRENT
CURRENT
OUTPUT
16A
3.5A
14A
14A
14A
14A
14A
4A
1A
1A
2A
1A
1A
4A
1A
1A
1A
1A
2A
1A
1A
Page 1 of 4
9.2/7.3A (Note 2)
4.6/3.9A (Note 2)
CURRENT (NOTE 1)
CURRENT (NOTE 3)
PEAK OUTPUT
PEAK OUTPUT
3.5A
3.5A
16A
16A
16A
16A
16A
7A
1A
1A
1A
1A
7A
1A
1A
6A
1A
1A
1A
1A
18A
Features
• RoHS lead-solder-exemption compliant
• Wide-range input for 110/220 VAC applications
• CE marked to Low Voltage Directive
• Input transient & ESD compliance to
• Meets EN55022, Class B limits
• TTL compatible Power Fail Signal
• Greater than 175,000 Hours MTBF
• Metric and SAE mounting inserts
MAP80 AC-DC Series Data Sheet
EN61000-4-2/-3/-4
REGULATION
REGULATION
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
LINE
0.2%
0.2%
0.1%
LINE
REGULATION
REGULATION
0.5%
±1%
LOAD
LOAD
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
RIPPLE & NOISE
%p-p (NOTE 2)
RIPPLE & NOISE
%p-p (NOTE 1)
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1.4%
0.5%
1%
www.power-one.com
-11.5V to -12.5V
-11.5V to -12.5V
-11.6V to -12.4V
-14.4V to -15.5V
-14.4V to -15.5V
11.9V to 12.1V
24.0V to 24.1V
11.5V to 12.5V
12.0V to 12.1V
11.6V to 12.4V
14.6V to 15.1V
24.0V to 24.1V
14.4V to 15.5V
11.76V to 12.15V
-4.8V to -5.4V
-4.8V to -5.4V
INITIAL SETTING
23.8V to 24.2V
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
INITIAL SETTING
5.0V to 5.1V
ACCURACY
ACCURACY

Related parts for MAP80-4003C

MAP80-4003C Summary of contents

Page 1

... Wide-range AC input and full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. The MAP80 utilizes a variable frequency design with a thermally efficient U-channel chassis to provide full power operation in convection-cooled applications. Design innovations include metric and SAE mounting inserts on each mounting surface to provide integration flexibility ...

Page 2

... TTL compatible logic signal. Time before regulation dropout Warning (Note 1) due to loss of input power at 110VAC. NOTES: 1) Power Fail Warning is not available on MAP80-1024. The MAP80-1012 is an open collector output, capable of sinking 35 mA, maximum. MCD10144 Rev. 1.0, 02-Feb-10 MAP80 AC-DC Series Data Sheet – ...

Page 3

... Add ‘C’ suffix to model number or order part number 412-59585-G separately. For convection cooled applications, derate output power to 65 watts on all multiple output models and MAP80-1005. Derate MAP80-1012 and MAP80-1024 to 75 watts. MCD10144 Rev. 1.0, 02-Feb-10 MAP80 AC-DC Series Data Sheet ...

Page 4

... Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10144 Rev. 1.0, 02-Feb-10 MAP80 AC-DC Series Data Sheet WEIGHT: 1.8 LBS (0.82 kg) Page www.power-one.com ...