no-image

MAP80-1012 POWER ONE

Manufacturer Part Number
MAP80-1012 POWER ONE
Description
SWITCHING POWER SUPPLIES, SINGLE OUTPUT, 80 WATTS
Manufacturer
POWER ONE
Type
Commercial, Industrialr
Datasheet

Specifications of MAP80-1012 POWER ONE

Brand/series
MAP80 Series
Configuration
Open-Frame
Current, Input
2.5 A (RMS)(90 VAC), 1.8 A (RMS)(110 VAC)
Current, Output
7.5⁄6 A (Max.)
Dimensions
7.20 in.(L) x 4.20 in. (H) x 1.80 in. (W)
Frequency, Operating
47 to 63 Hz (AC Input), 22 to 120 kHz (Operating)
Line Regulation
0.2 %
Load Regulation
±1 %
Mounting Type
Panel
Number Of Outputs
1
Operation
Switching
Output
12 VDC @ 7.5 A/15 VDC @ 6 A
Power, Output
80 W
Power, Rating
80 W
Primary Type
AC-DC
Special Features
TTL Compatible Power Fail Signal
Voltage, Input
90 to 135/175 to 264 VAC
Voltage, Output
12/15 VDC
En61000-4-2 Esd Level 4 (8 Kv)
All Map Products
En61000-4-3 Radiated Level 3 (10 V/m)
All Map Products
Universal Input
90-132 VAC or 175-264 VAC
Multiple Output Model Selection –
Description
Power-One’s MAP80 Series of power supplies provides reliable, tightly-regulated DC power for commercial and
industrial systems which require high peak current capabilities. Wide-range AC input and full international safety, EMI,
and ESD compliance ensure worldwide acceptance. All units bear the CE Mark.
The MAP80 utilizes a variable frequency design with a thermally efficient U-channel chassis to provide full power
operation in convection-cooled applications. Design innovations include metric and SAE mounting inserts on each
mounting surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections
or popular single-row Molex connector mating.
Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific
output voltage requirements.
Single Output Model Selection
MAP80-1005
MAP80-1012
MAP80-1024
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
MODEL
MAP80-4000
MAP80-4001
MAP80-4002
MAP80-4003
MAP80-4004
MODEL
2) MAP80-1012 output currents are expressed as 12V/15V operation. MAP80-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
12V/15V
24V/28V
VOLTAGE
VOLTAGE
OUTPUT
OUTPUT
+12V
+24V
+12V
+12V
+12V
+15V
+24V
+15V
-12V
-12V
-12V
-15V
-15V
+5V
+5V
+5V
+5V
+5V
-5V
-5V
5V
11.52V to 12.48V
23.04V to 24.96V
11.52V to 12.48V
14.40V to 15.60V
23.04V to 24.96V
11.5V to 15.5V
23.0V to 29.0V
4.5V to 5.6V
ADJUSTMENT
4.8V to 5.5V
4.8V to 5.5V
4.7V to 5.5V
4.8V to 5.5V
4.8V to 5.5V
ADJUSTMENT
RANGE
RANGE
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
80W Continuous Output Power
3.8/3.2A (Note 2)
7.5/6A (Note 2)
MAXIMUM OUTPUT
CURRENT
CURRENT
OUTPUT
16A
3.5A
14A
14A
14A
14A
14A
4A
1A
1A
2A
1A
1A
4A
1A
1A
1A
1A
2A
1A
1A
Page 1 of 4
9.2/7.3A (Note 2)
4.6/3.9A (Note 2)
CURRENT (NOTE 1)
CURRENT (NOTE 3)
PEAK OUTPUT
PEAK OUTPUT
3.5A
3.5A
16A
16A
16A
16A
16A
7A
1A
1A
1A
1A
7A
1A
1A
6A
1A
1A
1A
1A
18A
Features
• RoHS lead-solder-exempt compliant
• Wide-range input for 110/220 VAC applications
• CE marked to Low Voltage Directive
• Input transient & ESD compliance to
• Meets EN55022, Class B limits
• TTL compatible Power Fail Signal
• Greater than 175,000 Hours MTBF
• Metric and SAE mounting inserts
MAP80 AC-DC Series Data Sheet
EN61000-4-2/-3/-4
REGULATION
REGULATION
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
LINE
0.2%
0.2%
0.1%
LINE
REGULATION
REGULATION
0.5%
LOAD
±1%
LOAD
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
RIPPLE & NOISE
%p-p (NOTE 2)
RIPPLE & NOISE
%p-p (NOTE 1)
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1.4%
0.5%
1%
-11.5V to -12.5V
-11.5V to -12.5V
-11.6V to -12.4V
-14.4V to -15.5V
-14.4V to -15.5V
11.9V to 12.1V
24.0V to 24.1V
11.5V to 12.5V
12.0V to 12.1V
11.6V to 12.4V
14.6V to 15.1V
24.0V to 24.1V
14.4V to 15.5V
11.76V to 12.15V
-4.8V to -5.4V
-4.8V to -5.4V
INITIAL SETTING
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
23.8V to 24.2V
INITIAL SETTING
5.0V to 5.1V
ACCURACY
ACCURACY

Related parts for MAP80-1012 POWER ONE

MAP80-1012 POWER ONE Summary of contents

Page 1

... Wide-range AC input and full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. The MAP80 utilizes a variable frequency design with a thermally efficient U-channel chassis to provide full power operation in convection-cooled applications. Design innovations include metric and SAE mounting inserts on each mounting surface to provide integration flexibility ...

Page 2

... TTL compatible logic signal. Time before regulation dropout Warning (Note 1) due to loss of input power at 110VAC. NOTES: 1) Power Fail Warning is not available on MAP80-1024. The MAP80-1012 is an open collector output, capable of sinking 35 mA, maximum. MAP80 AC-DC Series Data Sheet – 80W Continuous Output Power ...

Page 3

... Cover Add ‘C’ suffix to model number or order part number 412-59585-G separately. For convection cooled applications, derate output power to 65 watts on all multiple output models and MAP80-1005. Derate MAP80-1012 and MAP80-1024 to 75 watts. MAP80 AC-DC Series Data Sheet Line to line Line to ground ...

Page 4

... Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MAP80 AC-DC Series Data Sheet WEIGHT: 1.8 LBS (0.82 kg) Page ...

Related keywords