SWS600L-24 TDK Corporation, SWS600L-24 Datasheet - Page 18

POWER SUPPLY 24V 27A SGL OUTPUT

SWS600L-24

Manufacturer Part Number
SWS600L-24
Description
POWER SUPPLY 24V 27A SGL OUTPUT
Manufacturer
TDK Corporation
Series
SWSr
Type
Commercialr
Datasheets

Specifications of SWS600L-24

Power Supply Type
Switching (Closed Frame)
Voltage - Output
24V
Number Of Outputs
1
Power (watts)
600W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 27A
Size / Dimension
7.48" L x 4.72" W x 2.4" H (190mm x 120mm x 61mm)
Power (watts) - Rated
648W
Operating Temperature
-20°C ~ 74°C
Efficiency
84%
Approvals
CSA, DENAN, EN, IEC, UL
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
27A
Power Rating
648W
Input Voltage
85V AC To 265V AC / 120V DC To 350V DC
Brand/series
SWS Series
Configuration
Enclosed
Output
24 VDC @ 27 A
Power, Output
648 W
Primary Type
AC-DC
Special Features
Parallelable, PFC, Remote On/Off, Remote Sense
Voltage, Input
85 to 265/120 to 350 VAC/VDC
Voltage, Output
24 VDC
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-20C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1742
SWS600L24

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SWS600L-24
Quantity:
119
18
SWS
Refer to the following fuse rating when selecting the external
fuses that are to be used on input line. Surge current fl ows
when line turns on. Use slow-blow or time-lag type fuse, not
fast-blow fuse. Fuse rating is specifi ed by in-rush current value
at line turn-on. Do not select the fuse according to input current
(RMS.) values under the actual load condition.
SWS600L : 15A  SWS1000L : 20A
The Fan-life has limitation. Therefore, periodic maintenance by
exchanging the life-expired fan is required for the power supply.
The following fi gure shows the life of fan.
(1) These products are designed for continuous operation
(2) These products are NOT suitable for use in the presence of
(3) These products are classed as ordinary equipment accord-
(4) Connect only apparatus complying with IEC/EN/UL60601-1
within an overall enclosure, and must be mounted such that
access to the mains terminals is restricted. See Clause 16,
IEC/EN/UL60601-1.
fl ammable anaesthetic mixtures with air or wish oxygen or
nitrous oxide.
ing to IEC/EN/UL60601-1 and are NOT protected against the
ingress of water.
to the signal ports.
9. Special instructions for IEC/EN/UL/CSA 60601-1 (SWS1000L only)
10
600L, 1000L
1
0
SWS600L, SWS1000L
Ambient temperature ( ℃ )
50
7. External Fuse Rating
8. Fan life expectancy
100
Fan acoustic noise:
SWS600L, SWS1000L: build in fan speed control circuit .
SWS600L/RF: 50dB[A]
(5) Except for permanently installed equipment as defi ned in
(6) When the PSU is installed within medical equipment an all
(7) Reference should be made to local regulations concerning
(8) These products have not been assessed to IEC/EN60601-1-2
SWS600L : 45dB[A] at room temperature, 50dB[A] at high
SWS1000L: 53dB[A] at room temperature, 55dB[A] at high
Clause 57.6 of IEC/EN/UL60601-1 the overall equipment in
which these products are installed must have double pole
fusing on the input mains supply. The products themselves
have single pole fusing in the live line.
pole mains input disconnect device must be fi tted.
the disposal of these products at the end of their useful life.
(EMC) but EMC test data is available from NEMIC-LAMBDA (S)
PTE LTD.
10
1
0
ambient temperature.
ambient temperature
SWS600L/RF, SWS1000L/RF
Ambient temperature ( ℃ )
・All specifications are subject to change without notice.
50
100

Related parts for SWS600L-24