SWS600L-48 TDK Corporation, SWS600L-48 Datasheet

POWER SUPPLY 48V SGL OUTPUT

SWS600L-48

Manufacturer Part Number
SWS600L-48
Description
POWER SUPPLY 48V SGL OUTPUT
Manufacturer
TDK Corporation
Series
SWSr
Type
Commercialr
Datasheets

Specifications of SWS600L-48

Power Supply Type
Switching (Closed Frame)
Voltage - Output
48V
Number Of Outputs
1
Power (watts)
600W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 13A
Size / Dimension
7.48" L x 4.72" W x 2.4" H (190mm x 120mm x 61mm)
Power (watts) - Rated
624W
Operating Temperature
-20°C ~ 74°C
Efficiency
84%
Approvals
CSA, DENAN, EN, IEC, UL
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
48V
Output Current
13A
Power Rating
624W
Input Voltage
85V AC To 265V AC / 120V DC To 350V DC
Brand/series
SWS Series
Configuration
Enclosed
Output
48 VDC @ 13 A
Power, Output
624 W
Primary Type
AC-DC
Special Features
Parallelable, PFC, Remote On/Off, Remote Sense
Voltage, Input
85 to 265/120 to 350 VAC/VDC
Voltage, Output
48 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1791
Q3860212
SWS600L-48
SWS600L48

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SWS600L-48
Quantity:
121
SWS-L Series
Compact and high-power AC/DC power supply

Related parts for SWS600L-48

SWS600L-48 Summary of contents

Page 1

SWS-L Series Compact and high-power AC/DC power supply ...

Page 2

・All specifications are subject to change without notice. ...

Page 3

... SWS600L-15 24V SWS600L-24 36V 18A SWS600L-36 48V SWS600L-48 60V 10A SWS600L-60 ( )=Peak Low Fan Noise The SWS-L is one of the quietest power supplies in their class. A temperature controlled fan adjusts its speed automatically, based on the temperatures surrounding the power supply. This substantially reduces annoying fan noise and wasted power consumption ...

Page 4

... However, it may not fulfi l all the specifi cations. (*13) Category 4 exposure levels: Trunk transportation over U.S. highways, composite two-wheeled trailer. (*14) As for DENAN, designed to meet at 100VAC. 4 SWS600L Specifications MODEL SWS600L-3 SWS600L-5 SWS600L-12 SWS600L-15 SWS600L-24 SWS600L-36 SWS600L-48 SWS600L-60 V AC85-265 or DC120-350 Hz % 70/72 ...

Page 5

... AND PEAK OUTPUT CURRENT ARE SHOWN ON THE NAME PLATE IN ACCORDANCE WITH THE SPECIFICATIONS 2:COUNTRY OF MANUFACTURE IS SHOWN ON THE NAME PLATE IN ACCORDANCE WITH THE SPECIFICATIONS 3:M4 TAPPED HOLES (12) FOR CUSTOMER CHASSIS MOUNTING (SCREW PENETRATION DEPTH 6m/m MAX.) 4:RECOMMENDED SCREW TORQUE OUTPUT TERMINAL (M5 SCREW)=2.5N・m INPUT TERMINAL (M4 SCREW)=1.27N・m SWS600L Output Derating 100 ...

Page 6

SWS 1000L ITEMS/UNITS Voltage Range (*3) Frequency (*3) Power Factor (115/230VAC) (typ) (*2) Input Effi ciency (115/230VAC) (typ) (*2) Current (115/230VAC) (typ) (*2) Inrush Current (typ) (*4) Leakage Current (typ) (*11) mA Nominal Voltage Maximum Current (Peak Current) (*1) Maximum ...

Page 7

SWS 1000L SWS1000L Outline Drawing ( 16.7 ) 4-M4 NAME PLATE CN3 LED CN2 CN1 OUTPUT TERMINAL (-) OUTPUT TERMINAL (+) ( 14 50 NAME PLATE == SWS1000L-24 INPUT :100-240VAC ∼ 13. ...

Page 8

... L LINE INPUT RECTIFIER FILTER 85∼265VAC N FG SWS600L * INPUT VOLTAGE RANGE : 85 ∼ 265VAC * FUSE RATING : 15A * PFC FREQUENCY : 100kHz BOOST MODE * DC-DC FREQUENCY : 300kHz FORWARD SWS1000L * INPUT VOLTAGE RANGE : 85 ∼ 265VAC * FUSE RATING : 20A * PFC FREQUENCY : 130kHz BOOST MODE * DC-DC FREQUENCY : 200kHZ FORWARD ...

Page 9

... The outputs of these products must be earthed in the end use equipment to maintain SELV. If the outputs are not earthed, they must be considered hazardous and must not be made user accessible. The output and control terminals of SWS600L-48 and SWS600L-48 / RF, SWS1000L-48 and SWS1000L48/RF are ELV. The output and control terminals of SWS600L-60 and SWS600L-60 / RF, SWS1000L-60 and SWS1000L60/RF are hazardous voltage ...

Page 10

... AC input terminal L : Live line (Fuse in line), M4 screw. ⑥ AC input terminal N : Neutral line, M4 screw. ⑦ Output terminal (SWS600L: M5 screw SWS1000L:φ9hall, M4 tapped hall x 2) ⑧ Output terminal (SWS600L: M5 screw SWS1000L:φ9hall, M4 tapped hall Terminal Explanation C N1 Configuration and Function CN1 and CN2 are same pin confi guration and function. They are connected to each other in this power supply unit ...

Page 11

... Remote ON/OFF control lines shall be twisted or used shielded wires. Separate from load line. ● Output current of each terminal screw shall be 60A or less for SWS600L. Panel Side ● Basic connection (Local sensing) Connect “+S” terminal to “+Vm” terminal and “-S” terminal to “ ...

Page 12

SWS 600L, 1000L Input Voltage Range Input voltage range is single phase 85 - 265VAC (47 - 63Hz) or 120 - 350VDC. Input voltage, which is out of specifi cation, may cause unit damage. Rated input voltage for safety standard ...

Page 13

SWS 600L, 1000L (a) AUX 2.2KΩ CNT1 150Ω CNT2 12V typ TOG G2 Example V1:5V R1:620Ω) (b) AUX 2.2KΩ CNT1 150Ω CNT2 12V typ TOG G2 (c) 2.2KΩ 150Ω 12V typ Fig.2.3 Examples of connecting remote ON/OFF circuit Output Ripple ...

Page 14

... Tester 14 Output - CNT・AUX・ALM : 100VDC 50MΩ or more Load Withstand Voltage SWS600L is designed to withstand 3.0kVAC, SWS1000L is de- signed to withstand 4.0kVAC between input and output. This series is designed to withstand 2.0kVAC between input and (chassis), 500VAC between output and 100VAC between output and CNT, AUX, ALM terminal each for Load 1 minute ...

Page 15

SWS 600L, 1000L Output - CNT· AUX · ALM : 100VAC 1min. (100mA) +S AC(L) +Vm + AC( COM PV CNT1 CNT2 TOG ALM AUX G1 G2 Output Voltage External Control (PV) Output voltage external control ...

Page 16

... SWS 600L, 1000L Mounting Directions Recommended standard mounting method is (A). Method (B) and (C) are also possible. Refer to the derating below. SWS600L (A) Mounting A (B) Mounting B (D) Inhibit (E) Inhibit SWS1000L (A) Mounting A (B) Mounting B V.ADJ + (E) Inhibit (D) Inhibit V.ADJ - V.ADJ Output Derating OUTPUT DERATING CURVE 100 ...

Page 17

... For safety and EMI considerations, connect terminal to the mounting set ground terminal, power supply and load mount- ing on aluminum plate is recommended for EMI setting. (6) Recommended torque for the terminal : SWS600L Input terminal (M4 screw) : 1.27 N · m (13.0kgf · cm) Output terminal (M5 screw) : 2.5 N · m (25.5kgf · cm) SWS1000L Input terminal (M4 screw) : 1.27 N · ...

Page 18

... Connect only apparatus complying with IEC/EN/UL60601-1 to the signal ports External Fuse Rating 8. Fan life expectancy Fan acoustic noise: SWS600L, SWS1000L: build in fan speed control circuit . SWS600L : 45dB[A] at room temperature, 50dB[A] at high SWS1000L: 53dB[A] at room temperature, 55dB[A] at high SWS600L/RF: 50dB[ 100 0 (5) Except for permanently installed equipment as defi ned in Clause 57 ...

Page 19

SWS 600L, 1000L 10. Before concluding that the unit is at fault Before concluding that the unit is at fault, make the following checks. (1) Check if the rated input voltage is connected. (2) Check if the wiring of input ...

Related keywords